The Battery bottom enclosure for 1P416S is one of the most important structural and thermal components in an energy storage system. As the bottom enclosure (battery tray), it carries the battery modules, provides mechanical support, and integrates liquid cooling to keep cells within a uniform temperature window. It directly influences temperature uniformity, cooling efficiency, sealing reliability, and overall battery lifespan.
This battery bottom enclosure is designed for 1P416S utility-scale BESS racks. Using a brazed aluminum alloy structure, it delivers uniform temperature control across large battery strings, reducing differential aging and extending the service life of utility storage assets.
| Performance | Parameter | Unit |
|---|---|---|
| Alloy | 3003mod | / |
| Cells | 280/314 | Ah |
| Regular size | flow plate 1.2 mm; flat plate 1.5 mm; flow height 3 mm | mm |
| Temperature difference | 3~5 | °C |
| Flow resistance | 15 | Kpa |
| Charge and discharge rate | 0.5 | C |
| Material | 3003 aluminum, Q235 steel | / |
| Surface treatment | Powder coating, Anodizing | / |
| Application | 1P416S utility-scale BESS | / |
It is engineered for the stated module, but hole positions, crossbeams, brackets, and overall dimensions can all be adjusted to your design.
The box body and related parts such as top cover, end plate, and coolant pipelines are also available.
There is effectively no MOQ. Customized samples can also be provided.
Full-process customized design, cross-component design collaboration, and design optimization and simulation.
Sample stage: 40-45 days. Mass production stage: about 35 days.