The JKD-517 is a standalone photoelectric smoke alarm developed for residential fire detection. It uses an optical sensing chamber to detect smoke particles generated during the early stages of many household fires, providing an audible warning when smoke reaches the specified alarm threshold.
Powered by two replaceable 1.5V AA batteries, the detector operates independently without requiring mains power, wireless communication or a mobile application. It is suitable for new residential installations, renovation projects and replacement programs where a standalone smoke alarm is required.
Manufactured according to EN14604:2005/AC:2008, the JKD-517 is available for OEM manufacturing, wholesale distribution and private-label cooperation for international customers. EN 14604 is the principal European standard for standalone residential smoke alarms.
Photoelectric smoke alarms are widely used in residential buildings because they respond to visible smoke particles commonly produced during smouldering fires.
The JKD-517 uses a photoelectric reflection sensor with a specified smoke sensitivity of 0.25dB/m, helping provide reliable smoke detection in accordance with its product specification.
For distributors and importers, choosing a photoelectric smoke alarm also aligns with the product category commonly specified for residential fire safety products in Europe.
The detector uses a photoelectric sensing chamber designed to detect smoke particles without using ionization technology.
Powered by 2 × 1.5V AA batteries, the detector remains operational even during a power outage and allows batteries to be replaced during the product's service life.
The JKD-517 is manufactured according to EN14604:2005/AC:2008, making it suitable for residential smoke alarm projects requiring this standard.
When smoke reaches the specified threshold, the detector activates an alarm of at least 85dB at 3 metres.
The standby current is specified at less than 50μA, while the alarm current remains below 70μA, supporting efficient battery operation.
The JKD-517 is suitable for:
The detector is designed for ceiling or wall installation, with a recommended coverage area of up to 40m² per room, subject to local installation requirements.
The JKD-517 is available for OEM manufacturing and private-label cooperation.
Customization options include:
All customized artwork is reviewed before production to ensure consistency with the approved technical documentation.
The JKD-517 is manufactured according to EN14604:2005/AC:2008.
Supporting documentation available upon request includes:
Customers should verify that all documentation corresponds to the exact product model and destination market before placing production orders.
Smoke alarm EN14604(CPR) Certi.pdf
| Item | Specification |
|---|---|
| Model | JKD-517 |
| Product Type | Standalone Photoelectric Smoke Alarm |
| Standard | EN14604:2005/AC:2008 |
| Sensor | Photoelectric Reflection |
| Power Supply | 2 × 1.5V AA Batteries |
| Smoke Sensitivity | 0.25dB/m |
| Alarm Volume | ≥85dB @ 3m |
| Silence Function | Approx. 10 Minutes |
| Product Life | 10 Years After Manufacture |
| Standby Current | <50μA |
| Alarm Current | <70μA |
| Operating Temperature | -10°C to +50°C |
| Humidity | <95% RH (Non-condensing) |
| Installation | Ceiling / Wall |
| Coverage Area | Up to 40m² |
| Dimensions | Φ120 × 39mm |
| Weight | 180 ±10g |
Photoelectric smoke alarms are designed to detect visible smoke particles commonly produced during many residential fires and are widely used in household fire protection.
No. This is a standalone smoke alarm and does not require Wi-Fi, Zigbee or an internet connection.
Yes. OEM branding, customized packaging and multilingual documentation are available.
Yes. Samples can be provided for evaluation before confirming mass production.
The JKD-517 is suitable for distributors, wholesalers, retailers, importers and fire safety brands looking for a standalone EN14604 smoke alarm.