The Parking Barrier Gate Loop Detector is a specialized sensor designed for parking barrier gates, capable of efficiently identifying and detecting all types of vehicles including oversized vehicles, trucks, motorcycles, and more, ensuring automatic gate opening and closing.
Sensitivity can be adjusted via the "Sensitivity" trimpot with 16 different settings (0 = least sensitive, "F" = most sensitive).
| DIP MODE | Relay B Output | Loop Coils Status |
|---|---|---|
| OFF OFF | When vehicle is moving out, output for relay B is 200m/s | Relay B Output Type |
| ON OFF | When the vehicle has left, output for relay B is 600m/s | Relay B will be present output. No Relay B Output Type |
| ON ON | Can be used to test the Loop. If the loop is faulty, Relay B will be on and it will switch off once the fault is fixed. |
| DIP MODE | Present Mode |
|---|---|
| ON | Vehicle can be permanently present (no auto-reset, unless vehicle has left or manual reset) |
| OFF | Normal mode (automatic reset after 30 minutes present of vehicle, used to solve mistake operation) |
| DIP MODE | Delay A Output |
|---|---|
| OFF OFF OFF | 0 sec Output |
| ON OFF OFF | 2 sec Output |
| OFF ON OFF | 5 sec Output |
| ON ON OFF | 8 sec Output |
| OFF OFF ON | 10 sec Output |
| ON OFF ON | 15 sec Output |
| OFF ON ON | 20 sec Output |
| ON ON ON | 30 sec Output |
| DIP MODE | Frequency |
|---|---|
| OFF OFF | High |
| ON OFF | Medium-High |
| OFF ON | Medium-Low |
| ON ON | Low |
When installing two or more loop detectors and sensing loops, set one detector to high frequency and the other to low frequency to minimize cross-talk effects. Position sensing loops and detectors at least 2m apart.
| Loop Perimeter | Cylinder Numbers |
|---|---|
| 3-4M | 6 |
| 4-6M | 5 |
| 6-10M | 4 |
| 10-20M | 3 |
| 20M-UP | 2 |
Loops are sealed using "quick-set" black epoxy compound or hot bitumen mastic to blend with roadway surface.
| Specification | Value |
|---|---|
| Self-tuning Range | 20-2000μH |
| Sensitivity | 16-way selectable / Highest 0.010% DL/L / Lowest 2.56% DL/L |
| Frequency | Four-step switch selectable 20-80KHz |
| Power Requirements | 110-240VAC (48 to 62Hz) |
| Operation Temp | -40℃ to +70℃ / (-111°F to +158°F) |
| Fault Output | Blinks slowly: short circuit or insufficient turns Blinks faster: open loop or excessive turns |
| Response Times | Turn-on 10-90MS / Turn-off 10-90MS |
| Visual Indications | Power LED - Red Channel LED - Green |
| Reset | Reset by push button on front enclosure |
| Relay Output | Presence relay / Fault relay |
| Humidity | Up to 95% relative humidity without condensation |
Our production line ensures efficient mass production, rigorous quality control, and thorough pre-shipment testing to deliver Loop detector products of the utmost perfection.