LD-200 Dual Channel Vehicle Detector
Double Coil Vehicle Loop Detector for Vehicle Counting Detection and Parking Management
Product Overview
Dual Channel Loop Detector for Parking Boom Barrier Gate 110-240VAC (48 to 63Hz) - Advanced vehicle detection system for parking management and access control applications.
Key Advantages
- Wide Sensing Range and High Sensitivity: Accurate detection of various vehicles with broad sensing range from 15 to 2000μH
- Automatic Reset Function: Enhances system stability by automatically resetting in case of malfunction
- Direction Recognition: Precise activation based on vehicle movement direction
- 40000V Lightning Protection: Robust protection ensures long-term durability
- Wide Operating Environment: Stable performance from -40°C to +70°C
Core Functionality
Vehicle Detection: Accurately detects vehicles using inductive sensing technology based on changes in inductance
Direction Recognition: Identifies specific vehicle movement directions for precise gate control
Automatic Reset: Eliminates manual intervention by automatically resetting during malfunctions
Relay Output: Provides relay output signals for gate control, traffic management, and vehicle counting
Applications
- Traffic Management Systems
- Gate Automation
- Parking Facilities Management
- Access Control Systems
- Traffic Light Control
- Vehicle Counting and Analysis
Product Images
Double Channel Car Parking Management Inductive Loop Detector
Loop Detector Connection Diagram
Sensitivity Selection Switches
Indicators and Switches
| Indicator |
Status |
Meaning |
| Power LED (RED) |
Illuminates |
Power ON |
| CH1 Detecting LED |
Continuous |
Vehicle detection |
| Slow Blinking |
Loop short circuit or insufficient twists |
| Fast Blinking |
Loop open circuit or excessive twists |
| CH2 Detecting LED |
Continuous |
Vehicle detection |
| Slow Blinking |
Loop short circuit or insufficient twists |
| Fast Blinking |
Loop open circuit or excessive twists |
Sensitivity Selection
Sensitivity and frequency adjustments using 7-way and 10-way dip switch settings:
- Dip switches 6, 7, 8 control CH1 sensitivity (0.8 to 0.015)
- Dip switches 3, 4, 5 control CH2 sensitivity (0.8 to 0.015)
Channel 1 Loop Function Selection
Special Functions Setting
CH1 and CH2 Sensitivity Selection
Frequency Setting
Reset Button Note: The LD-200 must be reset every time a setting change is made to the Dip switches.
Installation Guidelines
- Use ferromagnetic wires for induction coil (up to 500 meters total length)
- Coil cutting size: Rectangle 1.0-2.0m length * 0.8-1.2m width
- Avoid right angles at corners
- Keep product plug and socket in vertical direction during installation
Recommended Coil Installation Overview
Proper Installation Orientation
System Integration
JUTAI LD200/202 Double Channels Vehicle Loop Detector Series with direction recognition function for single-channel entry and exit applications.
Compatible Components
- JUTAI One door controller (Model: AC-11)
- JUTAI gate barrier (Model: BR-110)
- JUTAI long-range RFID reader (Model: PUHF-9)
- High-temperature resistance loop coils (Model: JTHT-11)
Operation Process
Entry Process
- Simultaneous Loop Coil Activation: Both loop coils are pressed when car enters
- UHF Reader Activation: LD-200/202 triggers UHF reader at entrance
- Card ID Reading: Reader transmits ID to controller via Wiegand output
- ID Verification and Gate Opening: Controller verifies ID and opens gate barrier
- Vehicle Entry: Barrier arm automatically lowers after vehicle passes
- Safety Assurance: LD-100/102 provides safety and anti-smashing functionality
Exit Process
- UHF Reader Activation: LD-200/202 triggers inside UHF reader
- ID Verification and Gate Opening: Controller verifies ID and opens exit barrier
- Vehicle Exit: Barrier arm lowers automatically after vehicle passes
- Safety Measures: LD-100/102 provides safety during exit process
Direction Recognition
Ensures double channels loop detector does not trigger signal again when car passes another UHF reader, maintaining accurate entry/exit records.
Direction Recognition Function
Independent Working Mode
The JUTAI LD-200/202 can function as two independent single-channel loop detectors for standard one-in and one-out parking lots:
- One loop coil triggers reader and reads card
- Other loop coil provides barrier anti-smashing function
- Cost-saving benefit by reducing hardware requirements
Independent Working Mode Configuration
Additional Product View
Product Installation Example
System Application Diagram