The JUTAI CL Series Photoelectric Safety Guard is a specialized protective solution engineered for high speed doors, offering flexible 8-beam or 16-beam configurations to match different safety requirements. It forms an invisible light grid between the emitter and receiver, instantly triggering door reversal or stopping when personnel, objects, or equipment intrude—effectively preventing pinching, crushing, or collision accidents in industrial and logistics environments. With IP67 protection and rugged aluminum alloy construction, it delivers reliable performance even in harsh conditions.
| Parameter | Specification |
|---|---|
| Model Series | CL05, CL10, CL15, CL20, CL25 (with -8L/16L suffix) |
| Beam Quantity Options | 8 beams / 16 beams |
| Protection Height | 500mm, 1000mm, 1500mm, 2000mm, 2500mm (model dependent) |
| Working Voltage | DC12-24V |
| Working Current | Transmitter: <65mA @DC12V; Receiver: <20mA @DC12V |
| Output Configuration | NO/NC relay output (default NO, configurable to NC); COM terminal included |
| Protection Rating | IP67 (dustproof + waterproof) |
| Housing Material | Aluminum alloy |
| Operating Range (Emitter to Receiver) | 1-8m |
| Beam Spacing | 100mm |
| Detection Precision | Detects objects as small as 50mm |
| Response Time | ≤20ms |
| Cable Length | Transmitter: 8m; Receiver: 4m |
| Connector Type | 5-pole M8 male connector (transmitter/receiver) |
| Operating Temperature | -20°C ~ +60°C |
| Key Function | High speed door anti-pinch protection + Blanking Mode (anti-false alarm) |
| LED Status Indicators | Transmitter: Steady blue (normal); Fast-flashing red (voltage <9V or >28V) Receiver: Steady red (blocked); Steady blue (unblocked); Flashing blue (misalignment) |
| Installation Hole Dimensions (Unit: mm) | 14, 29, 75, 80, 175, 19.7, 21.4, 259 |
| Component | Wire Color | Function | Notes |
|---|---|---|---|
| Transmitter | Red | DC12-24V Positive Power Supply | Connect to stable power supply; avoid overvoltage/undervoltage |
| Black | Ground (GND) | Connect to power negative terminal; ensure reliable grounding | |
| Green/Yellow/White | Reserve | No connection required for basic use | |
| Receiver | Red | DC12-24V Positive Power Supply | Same as transmitter power connection |
| Black | Ground (GND) | Shared ground with transmitter | |
| Green | NO/NC Output (Default NO) | Connect to door control system's safety signal input | |
| Yellow | Configurable NC | Activate via Blanking Mode setup | |
| White | COM (Common Terminal) | Matching terminal for NO/NC output |
| Model | Beam Quantity | Protection Height | Target Applications |
|---|---|---|---|
| CL05-8L/16L | 8/16 | 500mm | Small high speed doors, access doors in logistics centers |
| CL10-8L/16L | 8/16 | 1000mm | Medium-sized high speed doors, retail back entrance doors |
| CL15-8L/16L | 8/16 | 1500mm | Warehouse high speed doors, production line access doors |
| CL20-8L/16L | 8/16 | 2000mm | Large industrial high speed doors, cold storage fast doors |
| CL25-8L/16L | 8/16 | 2500mm | Extra-large high speed doors, loading dock doors |
| Fault Symptoms | Possible Causes | Solutions |
|---|---|---|
| Receiver's blue light flashes (power-on) | Emitter and receiver misalignment | Readjust positions to ensure parallel alignment |
| Transmitter's red light flashes fast | Power supply voltage <9V or >28V | Stabilize power supply to meet DC12-24V requirements |
| Safety guard works, but door has no anti-pinch action | Wiring error | Recheck wiring against the guide; ensure correct connection to door control system |
| Unable to enter Blanking Mode | 1. Light leakage during door descent 2. Bottommost beam blocked by debris 3. Door/obstruction fails to meet minimum continuous blocking distance | 1. Fix door sealing to prevent light leakage 2. Clear debris blocking the beam 3. Adjust door/obstruction to meet distance requirements |
For technical support, customization, or bulk inquiries, visit our official website: www.accesssecuritysolution.com