· Senseless flux vector control(VC)V/F(Voltage/Frequency)control
· Overload capacity is 60s for 150% of the rated current,3s for 180% of the rated current.
· There are ten auxiliary frequency sources.
· It can implement fine tuning of auxiliary frequency and frequency synthesis.
· Support PM motor(Z2000T series)
· Optional built-in EMC filter;Optional EtherCat communication.
· Power range:110v/220v/380v/415v/440v/480v 0.4-450kw
| Item | Z2000 series inverter | 
| Control mode | Senseless flux vector control(SFVC);Voltage/Frequency(V/F) control | 
| Maximum frequency | Vector control: 0-320Hz ; V/F control: 0-3200Hz | 
| Carrier frequency | 1-16kHz ;The carrier frequency is automatically adjusted based on the load features | 
| Input frequency solution | Digital setting: 0.01Hz Analog setting: maximum frequency x 0.025% | 
| Startup torque | G type: 0.5Hz/150%(SFVC) ; P type: 0.5Hz/100% | 
| Speed range | 1:100 | 
| Speed stability accuracy | ±0.5% | 
| Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current. P type: 60s for 120% of the rated current, 3s for 150% of the rated current. | 
| Torque boost | Auto boost ; Customized boost 0.1%-30.0% | 
| V/F cure | Line V/F curve; Multi-point V/F curve; N-powor VI/F curve | 
| V/F separation | Two types: complete separation; half separation | 
| Ramp mode | Straight-line ramp; S-curve ramp;Four groups of acceleration/deceleration time with the range of 0.0-6500.0s | 
| DC braking | DC braking frequency:0.0Hz to maximum frequency Braking time: 0.0~100.0s ; Braking action current value: 0.0%~100.0%  |  		
| JOG control | J0G frequency range:0.00-50.00Hz;JOG acceleration/deceleration time: 0.0~6500.0s | 
| Onboard multiple preset speeds  |  			lt implements up to 16 speeds via the simple PLC function or combination of X terminal states | 
| Onboard PID | t realizes process-controlled closed loop control system easily | 
| Auto voltage regulation (AVR) | It can keep constant output voltage automatically when the mains voltage changes | 
| Auto voltage/Over current stall control  |  			The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over voltage/over current | 
| Rapid current limit | It helps to avoid frequent over current faults of the AC drive | 