Low Voltage 380v 2.2kw T200-2R2G-4 VFD Inverter Motor Drive With STO Function
Micro AC Drive Advanced Frequency Inverter
· Cost effective;Micro compact design.
· Build-in EMC filter,24v DC power resource
· RS485,Ethercat,Profibus DP,CAN is optional
· VF control;Sensorless flux vector control
· External keypad interface RJ45
| Maximum frequency | Vector control:0~600Hz;V/F control:0-3200Hz | 
| Control mode | V/F control;Senseless flux vector control(SFVC); Closed loop vector control (CLVC) | 
| Carrier frequency |  			 0.5kHz~16kHz;The carrier frequency can be automatically adjusted based on the load feature  |  		
|  			 Input frequency resolution  |  			Digital setting:0.01Hz;Analog setting: maximum frequency×0.025% | 
| Startup torque | G Type:0.5Hz/150%(SFVC);P Type:0.5Hz/100% | 
| Speed range | 1:100(No PG) | 
| Speed stability accuracy | ±0.5%(No PG) | 
| Torque control accuracy | ±5%(FVC) | 
| Overload capacity |  			 G type: 60s for 150% of the rated current, 3s for 180% of the rated current;P type: 60s for 120% of the rated current, 3s for 150% of the rated current  |  		
| Torque boost | Fixed boost;Customized boost 0.1%-30.0% | 
| V/F curve |  			 Straight-line V/F curve;Multi-point V/F curve; N-power V/F curve (1.2-power, 1.4-power, 1.6- power,1.8-power, square)  |  		
| V/F separation | Two types: complete separation; half separation | 
| Ramp mode | Straight-line ramp;S-curve ramp Four groups of acceleration/deceleration time with the range of 0.00-6500.0s  |  		
| DC braking | DC braking frequency: 0.00 Hz to maximum frequency Braking time: 0.0-100.0s Braking action current value: 0.0%–100.0%  |  		
| JOG control |  			 Jog frequency range:0.00Hz~50.00Hz.  			Jog acceleration/deceleration time0.0s~6500.0s  |  		
|  			 Onboard multiple preset speeds  |  			It implements up to 16 speeds via the simple PLC function or by input terminal state | 
| Onboard PID | It realizes process-controlled closed loop control system easily | 
| Auto voltage regulation (AVR) | It can keep constant output voltage automatically when the mains voltage changes | 
| Over-voltage/Over-current stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over-voltage/over-current | 
| Rapid current limit | It helps to avoid frequent over-current faults of the inverter | 
| Torque limit and torque control | It can limit the torque automatically and prevent frequent over-current tripping during the running process | 
| Instantaneous stop doesn’t stop | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time | 
| Model | Input voltage | Rated output power(kw) | Rated input current(A) | Rated output current(A) | Motor power(kw) | 
| T200-2R2G-4 | 380V±15% | 2.2 | 5.8 | 5.0 | 2.2 | 


Q1:What is your MOQ?
 A: 1 pc
Q2:What's your terms of payment?
 A:T/T 100% before delivery.
Q3:What's your delivery time?
 A:Generally within 15 days after receiving full payment.
Q4:How can l get OEM/ODM order?