Specifications
Brand Name :
GFUVE
Model Number :
GF102
Place of Origin :
BEIJING,CHINA
MOQ :
1SET
Payment Terms :
T/T, Western Union, MoneyGram
Supply Ability :
1500SETS/MONTH
Delivery Time :
1-2WEEKS
Packaging Details :
CARTON
accuracy :
0.05%, 0.1%
power supply :
One Phase AC 100-265V, frequency 50/60Hz.
voltage output range :
57.7V, 100V, 220V, 380V; max 500V
current output range :
200mA, 1A, 5A, 20A, 100A; max 120A
frequency :
40Hz-70Hz
harmonic :
2-51times
dimension :
455x440x150MM
weight :
12KG
ambient temperature :
-10°C to +40°C
function :
Overload, short circuit, open circuit protection
Description
Electrical parameters
Accuracy class 0.05%, 0.1%
Power supply One Phase AC 100-265V, frequency 50/60Hz.
AC Voltage Output
Range 57.7V, 100V, 220V, 380V; max 500V
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.1% (Non-capacitive load)
Output load max 25VA
Measuring accuracy 0.05%RG
AC Current Output
Range 200mA, 1A, 5A, 20A, 100A; max 120A
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.1% (Non-capacitive load)
Output load max 50VA
Accuracy 0.05%RG
Power Output
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy 0.05%RG
Reactive power measuring accuracy 0.1%RG
Phase Output
Output adjustment range 0°-359.999°
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.05°
Power Factor
Adjustment range -1 ~ 0 ~ 1
Resolution 0.0001
Measurement accuracy 0. 0005
Frequency Output
Adjustment range 40Hz-70Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.005Hz
Voltage /Current/Harmonic Setting
Harmonic number 2-51times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power Energy Measurement Error
Active power energy 0.05%RG
Reactive power energy 0.1%RG
Power Pulse Output
Power pulse type active pulse, reactive pulse
Active power pulse output 5V,10mA
Power Pulse Input
Energy pulse type support active and reactive pulse, the highest frequency
power pulse input is 180K.
Mechanical parameters
Dimensions (W×D×H) (mm) 455x440x150
Weight (kg) 12
Environmental conditions
Ambient temperature -10°C to +40°C
Relative humidity 35%-85%

500V Manual Keyboard Electric Meter Calibration 70Hz Overload Protection

Send your message to this supplier
Send Now

500V Manual Keyboard Electric Meter Calibration 70Hz Overload Protection

Ask Latest Price
Brand Name :
GFUVE
Model Number :
GF102
Place of Origin :
BEIJING,CHINA
MOQ :
1SET
Payment Terms :
T/T, Western Union, MoneyGram
Supply Ability :
1500SETS/MONTH
Contact Supplier
500V Manual Keyboard Electric Meter Calibration 70Hz Overload Protection
500V Manual Keyboard Electric Meter Calibration 70Hz Overload Protection
500V Manual Keyboard Electric Meter Calibration 70Hz Overload Protection
500V Manual Keyboard Electric Meter Calibration 70Hz Overload Protection

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Active Member
8 Years
beijing, beijing
Since 2008
Business Type :
Manufacturer
Total Annual :
$100,000,000-$150,000,000
Employee Number :
300~350
Certification Level :
Active Member
Contact Supplier
Submit Requirement