RESIDENTIAL ENERGY STORAGE · 19-INCH RACK BATTERY
The YINTU YT-Racked ESS-5kWh is a low-voltage LiFePO4 battery module for residential energy storage. Each module provides 5.12 kWh nominal energy, 51.2 V nominal voltage and 100 Ah capacity in a standard 19-inch rack format. Its front LCD provides local battery information, while RS485, RS232 and CAN interfaces support communication with suitably matched equipment.
This is a DC battery module. A compatible external inverter is required to connect storage to household AC loads. Solar charging also requires a suitable external solar inverter or charge controller. YINTU supports product selection and system configuration in coordination with qualified manufacturing partners.
Consider this module for indoor residential solar storage, essential-load backup systems, and installer projects that use a rack-based battery layout. Solar self-consumption and backup operation depend on the selected inverter, system controls and installation design. The battery alone does not provide AC output or determine household backup power.

Illustrative installation. Rack, inverter, cabling and accessories are subject to the agreed supply scope.
PV panels connect to the compatible external solar inverter. The rack battery connects to the inverter through its battery DC interface, with an appropriate BMS communication connection. The inverter converts stored energy to AC for the selected household loads. Grid connection, charging permissions and backup circuits follow the capabilities of the chosen inverter and local installation requirements.

The diagram explains the system concept and is not an installation wiring drawing. Confirm battery voltage compatibility, communication protocol, inverter battery-current limits, protection devices and the final wiring design for each project.
| Parameter | YT-Racked ESS-5kWh |
|---|---|
| Battery chemistry | LiFePO4 |
| Cell configuration | 1P16S |
| Nominal energy | 5.12 kWh per module |
| Nominal capacity | 100 Ah |
| Nominal voltage | 51.2 V |
| Operating voltage range | 44.8–57.6 V |
| Recommended charge / discharge current | 50 A |
| Maximum continuous charge / discharge current | 100 A |
Nominal energy describes the battery rating. Deliverable AC energy and operating time depend on the allowed state-of-charge range, inverter losses, load profile, temperature and system settings. The datasheet does not specify a usable-energy value.
| Parameter | YT-Racked ESS-5kWh |
|---|---|
| Rack width | 19-inch standard |
| Dimensions (W × D × H) | 479.8 × 482 × 133 mm |
| Weight | 42 kg per module |
| Ingress protection | IP20 |
| Cooling method | Natural cooling |
| Charging temperature | 0 to +55°C |
| Discharging temperature | −20 to +55°C |
| Relative humidity | 5–95% RH |
| Operating altitude | 2,000 m |
Plan a dry, protected indoor location suitable for the IP20 enclosure. Check rack depth, module support, cable space, cooling clearance and the combined weight of the complete assembly before installation.
| Parameter | YT-Racked ESS-5kWh |
|---|---|
| Local display | LCD battery status display |
| Communication interfaces | RS485 / RS232 / CAN |
| Battery management | Multilevel safety management (BMS) |
| Cycle life, as listed | >6,000 cycles at 25°C; 70% EOF [1] |
| Listed standards, as supplied | IEC 62619 / UN38.3 / IEC610000-6-2/3 [2] |
[1] The datasheet states “70% EOF”; the cycle-life endpoint and complete test conditions require confirmation. This listing does not substitute a different endpoint definition.
[2] Standards are reproduced as listed in the supplied datasheet. The EMC designation “IEC610000-6-2/3” requires checking against the test report. Request model-specific certificates and reports to confirm applicability for the destination market.
The datasheet illustrates four modules in parallel, with 5.12 kWh per module. Four modules therefore represent 20.48 kWh of combined nominal energy by calculation. This example is not a stated maximum module count or a guarantee of a particular system power rating.
YINTU can help confirm the supported parallel arrangement, BMS settings, communication topology, cable and protection requirements, and inverter compatibility before the configuration is finalized. Later expansion should follow the approved manufacturer procedure and module-matching requirements.
It is the nominal energy of one module. The multi-module illustrations show an example arrangement and do not change the per-module rating.
No. Use a compatible external inverter and the required solar charging equipment. Confirm the complete equipment and protection arrangement for the installation.
The datasheet recommends 50 A for charging and discharging and lists 100 A as the maximum continuous current. The actual system setting must also respect the inverter, wiring, protection and operating-condition limits.
Compatibility is not established by the nominal voltage alone. Confirm the complete operating voltage range, communication protocol, current limits and approved configuration for the exact inverter model.
YINTU is an energy storage solution provider. We work with capable manufacturing partners to match battery products and system components to customer requirements, coordinate technical information, and clarify the proposed supply scope.
Send your country, inverter brand and model, required storage capacity, essential-load power, installation space and expected quantity. We can help review the configuration and prepare a project-specific quotation. Battery quantity, rack, inverter, accessories, warranty, lead time and commercial terms are confirmed in the written offer.
Source: YT-Racked ESS-5kWh English datasheet, V1.0 (2026.10). Specifications are subject to change without prior notice; final supply configuration is confirmed before order.