Adjustable High Voltage Pulse Generator 0-12kV HV Surge Device
Low Voltage Surge Generator
The XHHV512-12L low voltage pulse generator is a tie-rod portable integrated device, which is mainly used for shock discharge during low-voltage cable fault testing. The pulse generator adopts humanized design operation mode, high-precision dedicated high-voltage electronic components and high-frequency high-voltage technology, which is easy to operate, light in weight and easy to carry.
Panel Function Description
- Safety ground: The ground of the instrument shell must be reliably connected to the ground to prevent the instrument shell from being electrified .
- High-voltage ground: Also known as high-voltage tail, must be grounded reliably to prevent high-voltage leakage and discharge.
- Sampling ground: The negative terminal of the pulse energy storage capacitor has a high voltage and must be grounded reliably.
- Discharge button: Press to make contact with the ball gap for manual discharge (duration of each press cannot exceed 1s).
- High voltage start button: Press to start the device and generate high voltage output when the button light is on.
- High-voltage stop button: Press to cut off the high-voltage output when test is completed or an abnormality occurs.
- Over-current protection switch: Pressed position indicates over-current protection is active.
- Voltage adjustment: Turn knob clockwise to increase output voltage, counterclockwise to decrease.
- Power switch: "I gear" turns on AC 220V power, "0 gear" turns off system power.
- Fuse holder: Contains the fuse for the AC 220V power supply system.
- Power socket: AC 220V connection port.
- Time setting: Adjusts discharge time interval.
- Ammeter: Indicates current on the high voltage side.
- Voltmeter: High voltage output voltage indicating kV meter.
- High-voltage output (EMP): Connection point for high-voltage output line during impact discharge.
- High voltage output (DC): Connection point for high voltage output line during DC withstand voltage.
Technical Specifications
| Parameter |
Value |
| Impact high voltage |
0~12kV |
| High voltage partial pressure |
2.5 level |
| Built-in capacitor |
12μF |
| Output voltage polarity |
Negative polarity |
| Impact power |
250W@peak |
| Working mode |
Selectable or adjustable impulse rate and Single shot |
| Length of test cable |
High-voltage output line: 2m, Ground line: 3m, Power line: 1.8m |
| Minimum Output current in DC mode |
30mA at 12kV |
| Over temperature protection |
65ºC |
| Over current protection |
8mA (more than 3 seconds) |
| Power supply |
AC220V±15%, 50Hz±2Hz(60Hz) |
| Ambient temperature |
-20~+60ºC |