Specifications
Max Detection Depth :
≥10m
Display :
LCD with Ladder Diagram, Numeric, Backlight
Receiver Weight :
3 kg
Product Type :
Professional Underground Cable Fault Pinpointer
Signal Strength Range :
0-999
Delivery Time :
5-7 working days for stock, 15-25 days for production
Max Fault Resistance :
2MΩ
Receiver Battery :
7.4V Lithium, >8 Hours
Place of Origin :
Shaanxi, China
MOQ :
1 Set
Max Detection Range :
15km (Direct Method)
Gain Control Range :
0-100dB
Model Number :
XHGX507
Working Modes :
Peak / Trough / Step Voltage (A-Frame)
Price :
USD 1600-2800 / Set
Payment Terms :
T/T,L/C,PayPal,Western Union
Supply Ability :
200 Sets per Month
Packaging Details :
WNRLN branded rugged transport case with custom foam insert, export-grade corrugated carton
Transmitter Battery :
7.4V Lithium, 4-8 Hours
Operating Frequency :
LF, RF, 50Hz Passive
Detection Technology :
Electromagnetic Induction with Step Voltage
Operating Temperature :
-10°C to +55°C
Brand Name :
WNRLN
Signal Application Methods :
Direct / Coupling Clamp / Induction
Depth Accuracy :
LF ±(1-5)%, RF ±(5-12)%
Transmitter Weight :
4 kg
Certification :
ISO 9001:2015, CE
Description

Pro Underground Cable Fault Pinpointer XHGX507

The XHGX507 Pro Underground Cable Fault Pinpointer is a professional-grade electromagnetic induction detection system engineered for precise underground cable fault location. It excels at pinpointing cable-to-ground insulation faults up to 2MΩ using advanced step voltage detection technology, eliminating the need for high-voltage flashover equipment. Designed for street lighting cables, buried power distribution cables, and communication cable networks.

Key Features

Step Voltage A-Frame Fault Detection: Proprietary step voltage detection method pinpoints cable-to-ground insulation faults up to 2MΩ without high-voltage equipment. The A-frame accessory measures potential differences along the cable path to locate the exact fault point with zero potential crossing detection
2MΩ High-Resistance Fault Capability: Uniquely designed to locate high-resistance cable insulation failures that traditional time-domain reflectometry (TDR) and high-voltage surge methods struggle with. Ideal for single-phase metallic ground faults where discharge energy is insufficient for acoustic pinpointing
All-Digital LCD Display System: Large backlit LCD screen displays real-time signal strength ladder diagram (0-999), numeric value, gain level (0-100dB), frequency mode, battery status, and depth/current measurements. Voice FM tone prompt reduces operator eye fatigue during extended field work
Dual-Frequency Transmitter: Low Frequency (LF) for long-distance tracking up to 15km with minimal adjacent line interference, and Radio Frequency (RF) for high-resistance pipelines and poor grounding conditions with automatic impedance matching (5Ω-3000Ω)
Three Signal Application Methods: Direct connection for strongest signal and optimal accuracy; Coupling clamp for live (charged) cable detection without service interruption; Built-in induction antenna for areas where cable access is physically limited
Three Receiver Working Modes: Peak method for fast cable tracking, Trough method for precision positioning in low-interference environments, and Step Voltage method with A-frame for fault pinpointing
50Hz Passive Detection: Locate energized power cables by detecting their natural 50Hz frequency emission — no transmitter connection required, ideal for pre-excavation utility surveys
Depth and Current Measurement: Direct-reading digital depth display (up to 10m), plus 45-degree and 80% verification methods. Real-time current measurement distinguishes target cable from parallel adjacent pipelines even at different burial depths
Built-in Ohmmeter: Automatic loop resistance measurement and continuous auto-output impedance matching ensures optimal signal transmission regardless of soil conditions or cable type
Portable Field-Ready Design: Receiver 70cm × 20cm × 11cm (3kg), Transmitter 16cm × 16cm × 39cm (4kg). Both powered by rechargeable 7.4V lithium batteries. LCD backlight for night operation. Operating temperature range -10°C to +55°C

Technical Specifications

Receiver Unit
Operating Frequency Low Frequency (LF), Radio Frequency (RF), 50Hz Passive
Antenna Modes Peak Method (Horizontal Coil), Trough Method (Vertical Coil), A-Frame Step Voltage
Signal Strength Display Ladder Diagram + Numeric (0-999) with FM Tone Audio
Gain Control Manual Adjustable, 0-100dB Dynamic Range
Maximum Detection Depth ≥10m
Maximum Detection Range 15km (Direct Connection, Insulated Cable)
Depth Accuracy LF: ±(1-5)%, RF: ±(5-12)%
Battery 7.4V Rechargeable Lithium Battery
Battery Life Continuous >8 Hours, Standby >16 Hours
Dimensions 70cm × 20cm × 11cm
Weight 3 kg (with Battery)
Transmitter Unit
Operating Frequency Low Frequency (LF), Radio Frequency (RF)
Output Modes Direct Connection, Coupling Clamp, Induction (Built-in Antenna)
Matched Load Range 5Ω - 3000Ω (Automatic Impedance Matching)
Impedance Display 5-Digit LCD
Output Power Low / Medium / High (Selectable)
Battery 7.4V Rechargeable Lithium Battery
Battery Life 4-8 Hours (Frequency & Power Dependent)
Dimensions 16cm × 16cm × 39cm
Weight 4 kg (with Battery)
Fault Location Performance
Maximum Fault Resistance 2MΩ (Cable-to-Ground Insulation Fault)
Fault Detection Method Step Voltage with A-Frame / Electromagnetic Signal Drop Analysis
Fault Types Open Circuit, Short Circuit, Insulation Breakdown, Sheath Damage
General
Operating Temperature -10°C to +55°C
Thermal Protection Automatic Over-Current Protection
Display Backlight Yes (Night Operation Supported)
Audio Indication FM Tone Proportional to Signal Strength

Applications

Street lighting cable fault pinpointing (single-phase ground faults)
Buried LV/MV power distribution cable insulation fault location
Communication cable sheath damage and breakage detection
Cable-to-ground fault location for high-resistance faults where traditional methods fail
Pre-excavation underground utility mapping and cable route surveying
Live cable path finding via 50Hz passive mode or coupling clamp
Pipeline route tracing and depth measurement for water, gas, and metal pipe networks
T-junction and branch cable identification using current measurement comparison

Package Includes

1 x XHGX507 Pro Receiver Unit
1 x XHGX507 Pro Transmitter Unit
1 x A-Frame Step Voltage Fault Detection Accessory
1 x Coupling Clamp
1 x Direct Connection Cable Set (Red/Black)
1 x Ground Rod with Cable
2 x 7.4V Rechargeable Lithium Batteries
2 x Battery Chargers
1 x Rugged Transport Carrying Case
1 x User Manual
Send your message to this supplier
Send Now

Underground Cable Fault Pinpointer Advanced Pipe Locator System with Step Voltage A Frame Detection|XHGX507

Ask Latest Price
Watch Video
Max Detection Depth :
≥10m
Display :
LCD with Ladder Diagram, Numeric, Backlight
Receiver Weight :
3 kg
Product Type :
Professional Underground Cable Fault Pinpointer
Signal Strength Range :
0-999
Delivery Time :
5-7 working days for stock, 15-25 days for production
Contact Supplier
video
Underground Cable Fault Pinpointer Advanced Pipe Locator System with Step Voltage A Frame Detection|XHGX507
Underground Cable Fault Pinpointer Advanced Pipe Locator System with Step Voltage A Frame Detection|XHGX507
Underground Cable Fault Pinpointer Advanced Pipe Locator System with Step Voltage A Frame Detection|XHGX507
Underground Cable Fault Pinpointer Advanced Pipe Locator System with Step Voltage A Frame Detection|XHGX507
Underground Cable Fault Pinpointer Advanced Pipe Locator System with Step Voltage A Frame Detection|XHGX507

Xi'an Xu&Hui Electromechanical Technology Co., Ltd.

Verified Supplier
3 Years
Since 2013
Business Type :
Manufacturer
Total Annual :
1000000-5000000
Employee Number :
50~100
Certification Level :
Verified Supplier
Contact Supplier