MCDP Rubber Sheathed Cable , Low Smoke Zero Halogen Cable 0.38 / 0.66 KV
The Advantage Of Low Smoke Low Halogen Rubber
When a fire occurs, it can reduce the toxic gases, protect people's lives
Implemented standard
1 For the non-spread combustion cable, implement GB12972
2 For the flame-retardant cable, implement MT818
3 For the special mining cable(with bigger cross-section and higher voltage),implement the enterprise standard.
Brief introduction
1 Rated voltage of the cables is divided into 6 grades, which is 0.3/0.5kV,0.38/.066kV,1.9/3.3kV,3.6/6kV,6/10kV.
2 There are allowed long-term working temperatures of the cable conductor. For the cable of U(M)CPT-0.66/1.14, U(M)CPJB-0.66/1.14, U(M)CPJR-0.66/1.14 and 1.9/3.3kV, 3.6/6kV, 6/10kV, the temperature is 90℃;for the other, it is 65℃.
3 Minimum bending radius: For the cable of U (M)CPJB-0.66/1.14, U(M)CPJR-0.66/1.14,it is 15 times of the cable diameter; for the others, it is 6 times of the cable diameters.
4 The grounding wire should be well connected with the earth.
5The cable should be prevented from exposing to the sunshine for a long time.
Type and Name:
| Type | Description | Application |
| MC-0.38/0.66 | Rubber flexible cable for excavator | As the power connection used in the excavator |
| or similar equipment with rated voltage 0.38/0.66kV | ||
| MCP-0.38/0.66 | Shielded, rubber-sheathed flexible cable for excavator | As the power connection used in the excavator |
| or similar equipment with rated voltage 0.38/0.66kV | ||
| MCP-0.66/1.14 | Shielded, rubber flexible cable for excavator | As the power connection used in the excavator |
| or similar equipment with rated voltage 0.38/0.66kV | ||
| MCPJB-0.66/1.14 | Shielded ,monitoring and braiding reinforced type, | As the power connection used in the excavator |
| rubber flexible cable for excavator | or similar equipment with rated voltage 0.66/1.14kV, | |
| it can be dragged directly | ||
| MCPJR-0.66/1.14 | Shielded ,monitoring and braiding reinforced type, | As the power connection used in the excavator |
| rubber flexible cable for excavator | or similar equipment with rated voltage 0.66/1.14kV, | |
| it must be used in the protective chain panel | ||
| MCPT-0.66/1.14 | Metallic shielded rubber flexible cable for excavator | As the power connection used in the excavator |
| or similar equipment with rated voltage 0.66/1.14kV | ||
| MCP-1.9/3.3 | Shielded rubber flexible cable for excavator | As the power connection used in the excavator |
| or similar equipment with rated voltage 1.9/3.3kV | ||
| MCPT-1.9/3.3 | Metallic shielded rubber flexible cable for excavator | As the power connection used in the excavator |
| or similar equipment with rated voltage 1.9/3.3kV | ||
| MCPTJ-1.9/3.3 | Metallic shielded, monitoring type, rubber flexible cable for | As the power connection used in the excavator |
| excavator | or similar equipment with rated voltage 1.9/3.3kV | |
| MY-0.38/0.66 | Movable rubber flexible cable for mining | As the power connection used in the mining |
| machine with rated voltage 1.9/3.3kV | ||
| MYP-0.38/0.66 | Movable shield rubber flexible cable for mining | As the power connection used in the mining |
| machine with rated voltage 0.38/0.66kV | ||
| MYP-0.66/1.14 | Movable shield rubber flexible cable for mining | As the power connection used in the mining |
| machine with rated voltage 0.66/1.14kV | ||
| MYPJ-3.6/6 | Monitoring movable shield rubber flexible cable for mining | As the power connection used in the mining t |
| ransformer and similar equipment with rated voltage3.6/6kV | ||
| MYPTJ-3.6/6 | Metallic shielded monitoring type movable | As the power connection used in the mining |
| rubber flexible cable | transformer and similar equipment with rated voltage3.6/6kV | |
| MYP-3.6/6 | Movable shield rubber flexible cable for mining | Mining equipment with rated voltage 3.6/6kV |
| the min. environment temperature is-20℃ | ||
| MYPT-3.6/6 | Movable metallic shield rubber flexible cable for mining | Mining equipment with rated voltage 3.6/6kV |
| the min. environment temperature is-20℃ | ||
| MYPD-3.6/6 | Movable shield rubber flexible cable for mining | Mining equipment with rated voltage 3.6/6kV |
| the min. environment temperature is-40℃ | ||
| MYPTD-3.6/6 | Movable metallic shield rubber flexible cable for mining | Mining equipment with rated voltage 3.6/6kV |
| the min. environment temperature is-40℃ | ||
| MZ-0.3/0.5 | Driller cable for mining | As the power connection of driller with rated |
| voltage 0.3/0.5kV | ||
| MZP-0.3/0.5 | Driller shielded cable for mining | As the power connection of driller with rated |
| voltage 0.3/0.5kV | ||
| MYQ-0.3/0.5 | Movable light-type rubber flexible cable for mining | Lighting in the mine, as the power connection |
| of the interlock and control signals | ||
| used in the transport machine and equipment |
| CorexSize | Insulation Thickness | Overall diameter | ||||
| Phase | Grounding | Control | Phase | Thickness | MCDP 0.38/0.66 | |
| 3x16 | 1x4 | 3x2.5 | 1.6 | 4.5 | 33 | 38 |
| 3x25 | 1x6 | 4x2.5 | 1.8 | 5.5 | 39 | 45 |
| 3x35 | 1x6 | 4x4 | 1.8 | 5.5 | 42.5 | 48.3 |
| 3x50 | 1x10 | 4x4 | 2 | 5.5 | 47.5 | 54.5 |
| 3x70 | 1x16 | 4x6 | 2 | 6 | 53 | 60.5 |
| 3x95 | 1x25 | 4x6 | 2.2 | 6 | 59.5 | 67 |
| 3x120 | 1x25 | 4x6 | 2.4 | 6 | 63.5 | 72 |
| 3x150 | 1x35 | 4x10 | 2.4 | 6 | 68.5 | 76.5 |
| 3x185 | 1x35 | 4x10 | 2.6 | 6 | 74.3 | 82.5 |