Specifications
Brand Name :
Canon
Model Number :
E5877J-P1K
Certification :
CE, FDA
Place of Origin :
JAPAN
MOQ :
1
Payment Terms :
T/T
Nominal Entrance Field Size :
typ. 100 mm
Output Image Diameter :
20±1 mm
DC Power Supply Input Voltage :
100 to 240 Vac 30VA
Description

Canon X-Ray Image Intensifier E5877J-P1K with Adjustable FOV 4/2-inch Modes High Contrast PCB Inspection

The X-ray Image Intensifier E5877J-P1K is a high-performance industrial imaging option engineered to supply clear and detailed X-ray images. It boasts very high resolution and efficient soft X-ray penetration, rendering it perfect for non-destructive inspection applications in industries including electronics, automotive, and aerospace. This lightweight and compact equipment improves imaging efficiency and precision, guaranteeing dependable and accurate results.

100 to 240 Vac 30VA Xray Image Intensifier 4/2-inch FOV 110 Lp/cm Resolution

Key Features:
  1. Achieves very high resolution up to 110 Lp/cm in M mode for detailed imaging.
  2. Compact design with an overall length of 226 mm and a maximum diameter of 164 mm.
  3. Lightweight, weighing approximately 8.0 kg for easy integration and handling.
  4. CsI direct deposit input screen reduces X-ray scatter and improves detection efficiency.
  5. Anti-reflective coating on the output screen enhances image quality.
  6. Dual operation modes (N mode and M mode) for versatile imaging needs.
  7. Fast setup with a preheat time of less than 3 minutes.
  8. Compliance with international safety standards for reliable and safe operation.
Technical Datasheet:
Mechanical Specifications:
  • Overall Length: 226±3 mm
  • Maximum Diameter: 164±3 mm
  • Weight: approx. 8.0 kg
  • Nominal Entrance Field Size: typ. 100 mm
  • Output Image Diameter: 20±1 mm
Electrical Specifications:
  • Anode Voltage: 25 to 30 kV (N mode), 25 to 30 kV (M mode)
  • G3 Electrode Voltage: 1.5 to 3.5 kV (N mode), 9.0 to 12.0 kV (M mode)
  • G2 Electrode Voltage: 350 to 750 V (N mode), 150 to 550 V (M mode)
  • G1 Electrode Voltage: 50 to 250 V (N mode), 150 to 350 V (M mode)
  • Photocathode Voltage: 0 V
Power Supply Specifications:
  • DC Power Supply Input Voltage: 100 to 240 Vac 30VA
  • DC Power Supply Output Voltage: 24±1 Vdc
  • DC Power Supply Output Current: 400 mA max.
  • Weight: approx. 1 kg
Environmental Specifications:
  • Operating Temperature: 5°C to 40°C
  • Storage Temperature: -15°C to 45°C
  • Operating Humidity: 30% to 85% RH (non-condensing)
  • Storage Humidity: 10% to 90% RH (non-condensing)
  • Operating Pressure: 70 to 106 kPa
  • Storage Pressure: 50 to 106 kPa
Performance Specifications:
  • Central Resolution: 77 Lp/cm (N mode), 110 Lp/cm (M mode)
  • Conversion Factor (Gx): 90 cd/m2 (typ.) for 10 μGy/s (N mode), 90 cd/m2 (typ.) for 1 mR/s (M mode)
  • Contrast Ratio: 22:1 (10% area) (N mode)
Safety and Handling Specifications:
  • Maximum Fluoroscopic X-ray Tube Voltage: 125 kVp
  • Maximum Input Dose Rate: Continuous 4.37×10^-4 Gy/min [50 mR/min], Pulsed 8.73×10^-3 Gy/min [1 R/min]
  • Minimum Distance Between Focal Spot and Entrance Plane: 73 cm
Send your message to this supplier
Send Now

100 to 240 Vac 30VA Xray Image Intensifier 4/2-inch FOV 110 Lp/cm Resolution

Ask Latest Price
Brand Name :
Canon
Model Number :
E5877J-P1K
Certification :
CE, FDA
Place of Origin :
JAPAN
MOQ :
1
Payment Terms :
T/T
Contact Supplier
100 to 240 Vac 30VA Xray Image Intensifier 4/2-inch FOV 110 Lp/cm Resolution

SHENZHEN WEIMING PHOTOELECTRIC CO.,LTD.

Verified Supplier
1 Years
shenzhen
Since 2018
Business Type :
Manufacturer
Certification Level :
Verified Supplier
Contact Supplier