Frequently Asked Questions
1. What is a QJ deep-well submersible electric pump?
A QJ deep-well submersible electric pump is a vertical pump designed to operate underwater inside a deep well or borehole. It is primarily used to extract clean groundwater and deliver it to irrigation, water-supply, circulation or pressure-boosting systems.
2. What are the available flow and head ranges?
The available flow range is 5–1,500 m³/h, and the head range is 10–600 m. The actual flow and head depend on the selected pump model, number of hydraulic stages, motor power and system conditions.
3. Is the pump suitable for deep wells?
Yes. The QJ series is specifically designed for deep-well and borehole water extraction. The selected pump diameter must be compatible with the internal diameter of the well casing.
4. Can the pump be used for agricultural irrigation?
Yes. It can supply water to farmland, greenhouses, storage ponds, sprinkler systems and drip-irrigation systems. The required flow and pressure should be calculated according to the irrigation area, pipe network and irrigation equipment.
5. Can the pump be used for pressure boosting?
Yes. High-head models can be used in clean-water pressure-boosting systems. The pump can also be combined with a pressure tank, pressure sensor, control cabinet or variable-frequency drive for automatic pressure regulation.
6. Can it pump sewage or water containing large solids?
No. The QJ deep-well pump is mainly intended for clean water. Water containing large solids, long fibres, sludge or other abrasive materials may block or damage the hydraulic components. If the water contains sand or other particles, please provide a water-quality analysis before selecting the pump.
7. Can the pump handle water containing sand?
A small amount of fine sand may be unavoidable in some wells, but excessive sand can cause rapid wear to the impellers, guide vanes and bearings. The well should be properly developed and cleaned before pump installation. Please provide the expected sand content so that suitability can be evaluated.
8. Can the pump run without water?
No. Dry running must be avoided. The pump and motor rely on the surrounding water for cooling, and some internal components may also depend on water for lubrication. Dry-running protection and water-level control are strongly recommended.
9. Does a deep-well pump require priming?
Normally, no. Because the pump inlet is submerged below the water level, the pump does not require the suction priming procedure commonly associated with surface-mounted centrifugal pumps.
10. How deep should the pump be installed?
The pump inlet must remain sufficiently below the dynamic water level during operation. However, the pump should not be placed directly at the bottom of the well, where sand and sediment may accumulate. The final installation depth should be determined according to the static water level, dynamic water level, well depth and pump model.
11. How do I choose the correct pump diameter?
The pump's maximum outside diameter must be smaller than the internal diameter of the well casing, with sufficient clearance for installation, cooling-water circulation and future removal. Please provide the actual internal diameter of the well rather than only the nominal casing size.
12. How is the required pump head calculated?
The required head includes the dynamic water level, vertical lifting height, required outlet pressure and friction losses in pipes, valves and fittings. Selecting a pump based only on well depth may result in incorrect performance.
13. Can the pump operate automatically?
Yes. It can work with float switches, water-level probes, pressure sensors, control cabinets and variable-frequency drives. The system can be configured for automatic start and stop, constant-pressure water supply, dry-running protection and remote control.
14. Can a variable-frequency drive be used?
A variable-frequency drive may be used when the motor and control system are suitable for frequency control. It can help regulate flow, maintain constant pressure and reduce the impact of frequent starts. The permitted frequency range and cooling conditions must be confirmed before operation.
15. Can several pumps be used in one water-supply system?
Yes. Multiple pumps can operate alternately, in parallel or as duty-and-standby units. This configuration can provide variable capacity and improve system reliability. The pipeline and control system must be designed for multi-pump operation.
16. What causes insufficient water flow?
Possible causes include: incorrect pump selection, excessive total head, falling groundwater level, blocked inlet or hydraulic components, incorrect motor rotation, low supply voltage, worn impellers or guide vanes, excessive pipe resistance, or leakage in the rising pipe. The actual cause should be determined through systematic inspection.
17. What information is required for a quotation?
Please provide: required flow and head, well depth and internal diameter, static and dynamic water levels, water quality and temperature, power-supply voltage and frequency, required cable length, installation and control requirements, and intended application. For replacement projects, please also send the existing pump nameplate, performance curve, installation drawing or clear product photos.
18. Can the pump be customized?
Yes. The pump model, hydraulic stages, motor specification, cable length, discharge connection and control system can be configured according to the project conditions. Customization must be confirmed through technical pump selection before production.