Load Cell Signal Indicator Weighing Controller With 4-20mA Analog Output, COM RS232 RS485
Main Features:
1. Applications: Weight/Force Display, Peak Value Detection&Display Holding, Setpoint DO Output And AO/Digit Transmission.
 2. 4 Optional Setpoint DO Output Modes: Weight Limit DO Alarm Mode, Weight Increment DO Output Mode, Weight Decrement DO Output Mode And Weight Section DO Output Mode.
 3. EMC Design With High Anti-Jamming Capability, Suitable For Industrial Environment.
 4. 32-Bit ARM CPU With 48MHz Clock & Higher Arithmetic Speed.
 5. 5 Red LED Digital Tubes For English Character And Digit Display.
 6. 24-Bit High-Precision And High-Speed ∑-△A/D Conversion Module With 1/1,000,000 Internal Resolution And Sampling Frequency 1280Hz.
Technical Specification
1. Executing Standard
2. CMC GB/T 7724-2008PRC National Standard.
3. OMIL R76: 2006International Recommendation.
4. Accuracy Grade: III.
5. Verification Accuracy: 0.03%.
6. Static Weighing Accuracy: 0.2%~0.5%.
|  			 Power Supply  |  			 			 DC24V±20%  |  		
|  			 Display  |  			 			 5 Red Led Digital Tubes for English&Digit Display  |  		
|  			 Sampling Frequency  |  			 			 1280Hz  |  		
|  			 A/D Convert  |  			 			 24-bit  |  		
|  			 Keypad  |  			 			 4 keys for Shortcut mode operation with key tone  |  		
|  			 Excitation Voltage Output of Loadcell  |  			 			 DC5V  |  		
|  			 Max. Connection number of Loadcell  |  			 			 8 Loadcells (350Ω)  |  		
|  			 [mV]Signal Input Range  |  			 			 0-19.5mV  |  		
|  			 DO  |  			 			 2 Normally Open Transistor Switch Outputs  |  		
|  			 AO  |  			 			 1Analog Signal Output: 4~20mA.  |  		
|  			 Communication Port  |  			 			 COM1:RS232;COM2:RS485  |  		
|  			 Outline Dimension  |  			 			 107 × 60 × 100 mm (W×H×D)  |  		
|  			 Net Weight  |  			 			 Approx. 1.2kg  |  		
|  			 IP Grade  |  			 			 IP65  |  		
|  			 Verfication Accuracy  |  			 			 0.03%  |  		
|  			 Static Weighing/Force Measuring Accuracy  |  			 			 0.2%~.5~  |  		



Keypad Operation
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.
|  			 Menu Operation  |  		|
|  			 Key Name  |  			 			 Description  |  		
|  			 【■】  |  			 			 Enter Main Menu / Exit.  |  		
|  			 【8】  |  			 			 Enter / Save / Alarm Acknowledge.  |  		
|  			 【►】  |  			 			 Cursor shifts right. Display the previous option.  |  		
|  			 【▲】  |  			 			 Display the next interface or option. Digit input: +1 ( 0~9 loop).  |  		
Model Panel-mounting Operation Interface

Installation

Package