Packing Bagging Controller For Belt Feeding Double Hopper Packing Scale
   
   Main Features:
   	- Suitable for Ration Packing Scale. Optional Application Modes: Single-hopper-weighing Mode [Single-scale Mode], Double-hopper-weighing Mode [Double-scale Mode] and Bag-weighing Mode with Auto Bag-releasing or Manual Bag-releasing.
  	- EMC design with high anti-jamming capability, suitable for industrial environment.
  	- 32-bit ARM CPU with 48MHz clock & higher arithmetic speed.
  	- 6+8 Red LED digital tubes for English character and digit display.
  	- 4-key English keypad.
  	- Menu&Shortcut mode operation with key tone.
  	- 24-bit High-precision and high-speed ∑-△A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 400Hz.
  	- Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.
  	- Max. Connection Quantity: 4 Loadcells (350Ω).
  	- Auto Zero Initial Calibration after Power-on, Auto Zero Tracking, Zero Fine Adjustment, Zero Calibration and Load Calibration functions available.
  	- Optional Data Calibration function.
  	- Auto-locking, Key-locking, Key-unlocking, Digital Setting&Calibration and I/O Testing functions available.
  	- 6 Normally open switch inputs [DI] and 8 normally open transistor switch outputs [DO].
  	- Optional ‘High/Medium/Low Speed Feed’ DOs for feeding control. Optional Low-speed Feeding Modes: Continuous Feeding Mode and Inching Feeding Mode.
  	- 1 Optional and definable analog signal AO[4~20mA] for weight signal output or ‘High/Medium/Low Speed Feed’ control.
  	- Optional ‘Fall Value Auto Correction’ function.
  	- Optional ‘Auto Pause for Deviation Alarm’ function.
  	- Optional ‘Target Batch Control’ function [With Target Batch Count or Target Batch Weight finished, the packing process will stop automatically].
  	- 2 Communication ports [RS232&RS485] for connecting Host IPC/PLC and LED Remote Display.
  	- With the multitasking mode, the weighing&control process will not be interrupted by parameter setting and the other operations.
  
   
  Ration Packing/Bagging Controller Digital Scale Indicator Used On Packaging Scale
  Technical Specificat
     	- CMC GB/T 7724-2008PRC National Standard.
  	- OMIL R76: 2006International Recommendation.
  	- Accuracy Grade: III.
  	- Verification Accuracy: 0.03%.
  	- Static Weighing Accuracy: 0.2%~0.5%.
  	- Packing Accuracy: 0.2%~0.5%.
  
     	- 6+8 Red LED digital tubes for English character and digit display.
  	- Weight Display Range: -99,999~+999,999.
  	- Scale Capacity: Setting Range 1~999,999.
  	- Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.
  	- Display Resolution: 1/100,000.
  	- Weight Unit: Optional kg, t, g, none.
  	- Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000.
  	- Display Refreshing Time: Setting Range 0.01~1.00s.
  
     	- Model Panel-mounting: 4-key English keypad.
  	- Model Explosion-proof: 6-key English keypad.
  	- Menu&Shortcut mode operation with key tone.
  
     	- Excitation Voltage/Max. Current: DC9V/120mA [4-350Ω loadcells].
  	- Signal Input Range: 0~22.5mV.
  	- Output Sensitivity of Loadcell: 1.0~2.5mV/V.
  	- 24-bit ∑-△ADC with internal resolution 1/1,000,000.
  	- Sampling Frequency: 400Hz.
  	- Special anti-vibration digital filtering algorithm.
  	- Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
  	- Gain Drift: ±5ppm/℃.
  	- Non-linearity: 0.005%FS.
  
   	- Switch&Analog Signal Interface
  
   	- 6 Normally Open Switch Inputs [DI].
  	- 8 Normally Open Transistor Switch Outputs [DO]: DC24V, 250mA.
  	- 1 Optional&Definable Analog Signal Output [AO]: 4~20mA, Non-linearity: 0.05%FS.
  
   	
 	Digital Communication Interface  
   	- COM1: RS232.
  	- COM2: RS485.
  	- Connectable: Host IPC/PLC and LED Remote Display.
  
       	- Model Panel-mounting: DC24V±20%.
  	- Model Explosion-proof: AC110~240V, 50/60Hz.
  
   	- Max. Power Consumption: 5W.
  	- Outline Size
  
   	- Model Panel-mounting: 110×62×150mm [W×H×D].
  	- Model Explosion-proof: 256×290×166mm [W×H×D].
  
     	- Model Panel-mounting: 94×47 mm [W×H].
  
   	- Operating Temperature: -25℃ to +45℃.
  	- Storage Temperature: -30℃ to +60℃.
  	- Relative Humidity: Max. 85%RH.
  	- Application Environment of Model Explosion-proof
  
   	- Explosion gas environment: Zone 1&2.
  	- Classes of explosion gas mixture: IIA, IIB.
  	- Temperature grades of explosion gas mixture: T1~T6.
  	- Ex-mark: Ex d IIB T6 Gb.
  
     	- Front Panel of Model Panel-mounting: IP65.
  	- Model Explosion-proof: IP65.
  
     	- Model Panel-mounting: Approx. 0.5kg.
  	- Model Explosion-proof: Approx. 9.2kg.
  
  Keypad Operation
  If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.
   	 		 			| Menu Operation |  		
 		 			| Key Name |  			Description |  		
 		 			| 【MENU】 |  			 			 Enter Main Menu.   			Exit.  			 |  		
 		 			| 【ENT】 |  			Enter / Save / Alarm Acknowledge. |  		
 		 			| 【◄】 |  			 			 Cursor shifts left.   			Display the previous option.  			 |  		
 		 			| 【►】 |  			 			 Cursor shifts left.   			Display the next option.  			 |  		
 		 			| 【▲】 |  			 			 Display the next interface or option.   			Digit input: +1 ( 0~9 loop).  			 |  		
 		 			| 【▼】 |  			 			 Display the previous interface or option.   			Digit input: -1 ( 0~9 loop).  			 |  		
 		 			| Quick Operation |  		
 		 			|  			 【MENU】   			【Ñ】   			*  			 |  			 			 				- Key-locking.
  				- Key-unlocking.
  			  			 |  		
 		 			|  			 【◄】   			(【SET】)  			 |  			Recipe parameters setting. |  		
 		 			|  			 【◄】   			【ZERO】   			【→0←】   			*  			 |  			 			 				- [-ZEro-]: Zero Calibration with Power-down Protection and Clearing Tare Weight.
  				- [≡ZEro≡]: Zero Fine Adjustment without Power-down Protection and without Clearing Tare Weight.
  				- The controller will switch to Gross Weight display.
  			  			 |  		
 		 			|  			 【▲】   			【TARE】   			【→T←】   			*  			 |  			 			 				- [≡tArE≡]: Manual Tare without Power-down Protection.
  				- [-PStr-]: Preset Tare Weight with Power-down Protection.
  				- [-rStr-]: Clear Tare Weight with Power-down Protection.
  				- The controller will switch to Net Weight display.
  			  			 |  		
 		 			|  			 【ENT】   			【G/N】  			 |  			Gross Weight / Net Weight display switch. |