Specifications
Brand Name :
Wayeal
Model Number :
GC6100
Certification :
ISO, CE
Place of Origin :
Anhui, China
MOQ :
1
Price :
Negotiation
Payment Terms :
L/C, T/T
Supply Ability :
15 Pieces per month
Delivery Time :
30 days
Packaging Details :
One piece per wooden case
Name :
GC System
Detection Limit :
2×10 -12g/s
Detector :
FID Detector
Column Quantities :
2 Columns
Qualitative repeatability :
≤0.05%
Position :
16
Description

GC6100 Gas Chromatography with FID Detector
Technical Parameters of GC6100 Gas Chromatography

Power Supply220V ±10%, 50Hz ±2%
Ambient Temperature5°C to 40°C
Relative Humidity20% to 85%
Technical Specifications
Retention Time repeatability<0.008% or <0.0008min
Peak Area Repeatability≤0.5% RSD
Injection Port
Injection PortSplit/Splitless
Maximum Operating Temperature450°C
Control Precision0.001 psi
Control Range0–100 psi
Gas Control ModesConstant pressure, constant flow, programmed pressure/flow ramps
Maximum Split Ratio12,500:1
Optional Carrier GasesN₂, H₂, He, Ar
Flow Rate Range (N₂ as carrier gas)0–500mL/min
Column Oven
Temperature Range Ambient +4°C to 450°C
Programmable Temperature Ramps32 steps/33 platforms
Maximum Heating Rate≥75°C/min
Cooling Time (22°C ambient)From 450°C to 50°C in <5 minutes
Maximum Program Run Time9999.99 minutes
FID Detector
Maximum Operating Temperature450°C
Minimum Detectability≤1.5pg/s
Linear Range≥10⁷
DataAcquisition RateUp to 1000 Hz (provide proof of software interface)
ECD Detector
Minimum Detectability≤4×10⁻¹⁵ g/mL
Linear Rang≥10⁴
TCD Detector
Sensitivity≥60,000 mV·mL/mg
Linear Range≥10⁴
Instant Noise≤0.1 mV
Baseline Drift≤0.2 mV
Autosampler
Sample Capacity16 positions
Solvent Bottle Positions2
Waste Bottle Position1
Syringe Cleaning ModesStandalone, pre-injection, post-injection
Injection Volume0.1–5μL

Product Performance

1. High precision

1.1 Very low noise, FID noise is better than the international leading level;
1.2 High sensitivity detector, low baseline drift;
1.3 Good reproducibility of peak area and retention time;

1.4 High temperature control accuracy and good stability, the column thermostat provides a constant temperature environment for the effective separation and detection of various components.

2. Flexibility and scalability

2.1 Optional multiple detectors (FID, FPD, ECD);
2.2 Any two detectors and two chromatographic columns can be installed at the same time; It can have three independent circuits, gas system and three signal output terminals at the same time;

2.3 Flexible syringe injection system, optional autosampler or six-port valve injection.


Product Application

Environmental Protection: Trace Toxicants in Air and Water Contaminated Areas Analysis, monitoring and research

Biochemistry: clinical applications, pathology and toxicology studies.
GC6100 Gas Chromatography with FID Detector



Send your message to this supplier
Send Now

GC6100 Gas Chromatography with FID Detector

Ask Latest Price
Brand Name :
Wayeal
Model Number :
GC6100
Certification :
ISO, CE
Place of Origin :
Anhui, China
MOQ :
1
Price :
Negotiation
Contact Supplier
GC6100 Gas Chromatography with FID Detector

Anhui Wanyi Science and Technology Co., Ltd.

Verified Supplier
4 Years
anhui, hefei
Since 2003
Business Type :
Manufacturer, Exporter
Total Annual :
50 Million-100 Million
Employee Number :
1300~1500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement