EDI Automobile Exhaust Gas Treatment Solution Production And Purification Equipment
EDI main economic and technical indicators
- Pretreatment flow ≥2.5T/H;
- The first-level reverse osmosis product water ≥1.5T/H;
- Secondary RO water production ≥1T/H;
- The first-level reverse osmosis conductivity ≤15μs/cm;
- The conductivity of secondary reverse osmosis ≤10μs/cm;
- EDI product water resistivity ≥14MΩ·CM;
- Polishing mixed bed water production resistivity ≥17MΩ·CM (using nuclear grade resin) (25L inside, 35-50 tons of water per liter);
- EDI product water flow ≥1000L/H;
- Utilization rate of primary reverse osmosis water ≥65%;
- The utilization rate of secondary reverse osmosis water is ≥85%;
- EDI water utilization rate ≥90%;
- EDI service life: 3-5 years (the membrane block needs to be cleaned when the water quality and water volume do not meet the standards).
EDI Technical Parameters
| TEA(With CO2) | <25mg/LasCaCO3 | PH | 5-9 |
| Hardness | <0.1mg/LasCaCO3 | Silicon | <0.5mg/L |
| TOC | <0.5mg/L | Residual chlorine | <0.05mg/L |
| Fe,Mn,H2s | <0.01mg/L | Water inlet pressure | 30100PSI |
EDI (Electro Deionization) Inlet Water Requirements
| Item | technical requirements |
| Water supply | RO produces water, conductivity ≤20μs/cm (recommended <10μs/cm) |
| PH value | 6.0~9.0(recommended7.0~9.0) |
| Water temperature | 5~35℃ |
| Hardness (calculated as CaCO3) | <0.5ppm |
| Organic matter | <0.5ppm |
| Oxide | ≤0.05ppm(Cl2),0.02ppm(O3), |
| Fe,Mn | ≤0.01ppm |
| Silica | <0.5ppm |
| Carbon dioxide | <5ppm |
| Oil and grease | can not be detected |