Ultra-Filtration Membrane By Reinforced Hollow Fiber Membrane
Specifications
| Module | UF-4021 | UF-4040 | UF-8040 |
| Size (mm) | Ø101*533.4 | Ø101*1016 | Ø201.9*1016 |
| Module type | Inside-out | Inside-out | Inside-out |
| Shell and seal materials | PVC,epoxy resins | PVC,epoxy resins | PVC,epoxy resins |
| Membrane Material | PAN | PAN | PAN |
| Max operating pressure psi(Mpa) | 43(0.3) | 43(0.3) | 43(0.3) |
| Suggest operating pressure psi(Mpa) | <15(0.1) | <15(0.1) | <15(0.1) |
| Max trans-membrane pressure psi(Mpa) | 29(0.2) | 29(0.2) | 29(0.2) |
| Operating temperature | 5~40℃ | 5~40℃ | 5~40℃ |
| Effective membrane area | 4m2 | 2m2 | 18m2 |
| Design flux | 40-150L/m2/h | 40-150L/m2/h | 40-150L/m2/h |
| Molecular Weight Cut off(Dalton) | 50,000 | 50,000 | 100,000 |
| Hollow fiber id/od size | 1.0mm/1.6mm | 1.0mm/1.6mm | 1.0mm/1.6mm |
| Hollow fiber quantity | 1400 | 1400 | 7300 |
| PH range | 3~9 | 3~9 | 3~9 |
| Initial flux | 0.8m3/h | 0.8m3/h | 4m3/h |
| Feed water turbidity NTU | <70 | <70 | <70 |
| Produced water turbidity NTU | <1 | <1 | <1 |
| Feed water turbidity residual chlorine ppm | <70 | <70 | <70 |
| Feed water pollution index( SDI 25) | <25 | <25 | <25 |
Application
- Pre-filtration for RO system
- Solvents, selected acids & lyes, chemical industry.
- Semiconductor, Electronic industry ultrapure water system
- Food and beverage
- Oil and Gas industry.
- Pharmaceutics
- Paints, coatings and plating solutions
Advantages of Our MBR Modules:
- All the modules have an added patented design air blowing tube to enhance the efficiency of the air blowing onto the membrane surface.
- Permanent Hydrobility Membrane
- Strong strength, the broken strength more than 50MPa
- Excellent performance and Low cost
UF membrane application
- Industrial waste water treatment and reuse;
- Pretreatment of RO&NF.
- Drinking water treatment of tap water, surface water, well water and river water;
- food and beverage processing;
- sea water desalination engineering.