Specifications
Place of Origin :
China
Energy Consumption Profile :
Longer Evening and Overnight Operation
Storage Care Requirement :
Periodic Maintenance Charging during Long Storage
Model Number :
BAT-18KWH-51.2V-A
Delivery Preparation :
Heavy Floor - Standing Equipment Access Required
Capacity Comparison Input :
Daily Energy , Charging Power and Reserve Period
Payment Terms :
L/C,T/T,Western Union
Delivery Time :
10-15 days for sample orders (1-2 pcs), and bulk orders over 2 pcs are negotiable.
Brand Name :
Voltertech
MOQ :
2 Units
Supply Ability :
5000 Sets per Month
Certification :
CE , MSDS
Project Deployment Type :
Large Homes , Farms , Clinics and Retail Sites
Price :
Negotiable
Backup Reserve Strategy :
Maintain Additional Energy for Priority Loads
Packaging Details :
Heavy-Duty Wooden Case with Protective Foam
Recharge Planning Priority :
Restore Daily Battery Use within Available Time
Capacity Upgrade Level :
Higher - Capacity Option above the 15kWh Model
Description

18kWh 51.2V Floor Standing Lithium Battery with 346Ah and 10kW Output

This 18kWh floor standing lithium battery is the higher-capacity option for projects that require more stored energy than the 15kWh configuration. Its 51.2V, 346Ah LiFePO4 platform is suitable for larger homes, farms, clinics, shops and small commercial energy systems.

The increased capacity is intended to extend the available energy reserve rather than increase inverter output. A compatible external inverter remains necessary for solar charging and AC load supply.

More Energy for Longer Operating Periods

The stated 18,000Wh capacity provides additional energy for projects with higher evening consumption, longer overnight operation or a greater backup reserve for priority equipment.

This model can be considered when the 15kWh battery is close to the calculated daily requirement and the buyer wants additional operating margin. Final capacity should still be selected from actual watt-hour consumption rather than product size alone.

Plan Enough Charging Energy for Daily Recovery

A larger battery requires an appropriately sized solar array, inverter charger or other AC charging source. The charging system should replace the energy used during the available solar or utility charging period.

The battery supports up to 150A of continuous charging and 200A of continuous discharging. These values are maximum limits; actual settings should be selected according to the inverter and required operating strategy.

CAN, RS485 and RS232 communication interfaces support integration with compatible inverter and monitoring equipment. Protocol compatibility should be confirmed before production.

Project Delivery and Long-Term Storage

The battery weighs approximately 163kg. Site access, unloading arrangements, floor strength and the final installation position should be prepared before delivery.

The IP22 enclosure requires a dry indoor or protected technical location. For extended storage periods, the specification requires a maintenance charge at least once every three months.

The stated 18kWh is nominal DC battery energy. The energy delivered to AC loads will vary with inverter efficiency, operating settings and system losses.

18kWh Floor Standing Battery Specifications

Energy Storage Platform 51.2V LiFePO4 Battery System
Stated Capacity 346Ah / 18000Wh
Charge and Discharge References 58.4V Charge Cut-Off / 56V Float / 44V Discharge Cut-Off
Maximum Operating Current 150A Continuous Charge / 200A Continuous Discharge
Battery Power Reference 10000W Rated Output
Data Interfaces CAN / RS485 / RS232
Battery Management Protection Overcharge / Overdischarge / Overcurrent Protection
Project Logistics 163kg Net Weight / IP22 Enclosure
Environmental Requirements Discharge -20°C to 55°C / Charge 0°C to 55°C / 5–90% RH / ≤4000m

18kWh Capacity and Deployment FAQ

When should a project choose 18kWh instead of 15kWh?

The 18kWh option is more suitable when the calculated daily energy use approaches the smaller battery capacity or additional reserve is required.

Does the higher capacity increase the maximum AC load?

Not automatically. Maximum AC load is determined by the external inverter and battery-current settings.

How should the charging system be sized?

It should be based on daily battery use, available sunlight, inverter charging power and the time available to restore the energy reserve.

What should be prepared before the battery arrives?

Confirm the unloading route, stable floor location, ventilation, cable access and protection from water or condensation.

Does the battery require attention during long storage?

Yes. The specification requires a maintenance charge at least once every three months during storage.

Compare Energy Use with Charging Capacity

Send the daily consumption, charging source and required reserve period. We will help determine whether the 18kWh capacity provides a meaningful project advantage.

Request an 18kWh Capacity Assessment

Send your message to this supplier
Send Now

18kWh 51.2V Floor Standing Lithium Battery with 346Ah and 10kW Output

Ask Latest Price
Place of Origin :
China
Energy Consumption Profile :
Longer Evening and Overnight Operation
Storage Care Requirement :
Periodic Maintenance Charging during Long Storage
Model Number :
BAT-18KWH-51.2V-A
Delivery Preparation :
Heavy Floor - Standing Equipment Access Required
Capacity Comparison Input :
Daily Energy , Charging Power and Reserve Period
Contact Supplier
18kWh 51.2V Floor Standing Lithium Battery with 346Ah and 10kW Output

Voltertech Co.,Limited

Verified Supplier
1 Years
guangdong, guangzhou
Business Type :
Manufacturer
Total Annual :
5000000-10000000
Employee Number :
50~100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement