LCD Display Multifunction Process Calibrator
     
    VICTOR 04S Temperature calibrator Voltage/mA Source multifunction Input and Source calibrator Large LCD display with 0.05% accuracy
     
       
    I. Basic characteristics of the product
      	- Analog output characteristics
   
        DC voltage DCV, DC current DCI
      	- The maximum output accuracy is 0.05% and the output display is 5 digits.
   	- Output settings can be manually increased or decreased by position.
   	- DCI output includes active output (internal 24V power supply), and passive output (external 24V power supply).
   	- mA is equipped with the percentage display mode.
   	- Upon DCI output, manual stepping and automatic waveform output functions may be available.
   
    Manual step output includes: 25% stepping and 100% stepping.
    Output current 0-20mA or 4~20mA is optional.
    Automatic waveform output includes: automatic stepping, sawtooth wave and triangular wave and the automatic waveform operation parameters can be configured.
      	- Internal 24V loop power is provided.
   	- Maintenance setup function, including:
   
    Auto power-off, backlight, flashlight
          	- The segment code is displayed on an LCD with a white backlight.
   	- It has a LED flashlight for lighting.
   	- It is powered by 3 AA battery cells. The battery compartment door is convenient for battery replacement. Low-battery detection is available.
   	- It is small, firm, reliable, suitable for field use, and cheap.
   	- User-optional large-suction magnetic sling is provided.
   
        
      II. Basic function and performance of the product (technical index)
     
    Analog output function [Used within one year after calibration, 23 ℃± 5 ℃, 20-70% RH, accuracy=± (% set value+% reading)]
      	  		  			| Output function |   			Range |   			Output range |   			Resolution |   			Accuracy |   			Remarks |   		
  		  			|   			 DC voltage     			DCV   			 |   			10V |   			-1.000V-11.000V |   			0.001V |   			0.05%+2mV |   			Maximum output current: 5mA |   		
  		  			|   			 DC current     			DCI   			 |   			30mA |   			0.000mA-30.000mA |   			0.001mA |   			0.05%+4uA |   			  			 At 20 mA, the maximum load is 1000Ω     			Upon transmitter simulation, the external loop power supply is 5-28V   			 |   		
  	  
     
     
    Other characteristics:
      	- Uncertainty includes standard uncertainty, hysteresis, nonlinearity, repeatability, and typical long-term stability over the period mentioned (K = 2).
   	- Maximum applied voltage at input end: about 30Vpk; Maximum applied current at input end: about 25mA
   	- Load characteristics: capacitive load ≥0.01uF (DCV/OHM/TC/RTD/FREQ); Inductive load ≥ 0.01uF 100uH (DCA)
   
    Output load affects DCmV (0.001% full scale + 1nV)/mA; DCV (0.001% full scale + 1nV)/mA
      	- The temperature range of internal temperature compensated sensor RJC is -10 to 50C. The temperature measurement accuracy at 18 to 28C is ±0.5C, and the temperature measurement accuracy at other temperature is ±1C. Cold end compensation time is 10S/ times.
   	- Temperature coefficient: 0.1 × basic accuracy/℃ (temperature range < 18℃ or > 28℃)
   
     
      	- Coefficient: 0.1 × basic accuracy/℃ (temperature range: <18℃ or >28℃)
   
     
     
        
    III. General characteristics of the product
      	- Operating temperature and humidity: 0 to 50ºC ≤80%RH without condensation; 40 to 50ºC ≤70%RH.
   	- Storage temperature and humidity: -25 to 60ºC ≤90%RH without condensation.
   	- Electrical safety: EN61010-1:2001
   
    Withstand voltage: AC3540V(50/60Hz)/5 seconds between terminal and housing.
    Insulation impedance: DC1000V/100MΩ or more between terminal and housing.
      	- Electromagnetic compatibility (EMC): EN61326-1:2006
   
    Performance criterion 2 is met, i.e. the function and performance are temporarily reduced or lost, but can be recovered by themselves.
      	- Protection grade IP40.
   	- Vibration and fall: IEC 60068-2-64:2008, IEC 60068-2-32:2008
   	- Random, 2g, 5-500Hz; 1m drop test.
   	- CE certification.
   	- Quality standard: developed, designed and manufactured in accordance with TUV ISO 9001.
   	- Calibration period and preheating time:
   
    To ensure the accuracy of the Table, the calibration period is one year.
    The startup preheating time is more than 30 minutes.
      	- Instrument display and key
   
    Segment code LCD display, white backlight
    Rubber key is adopted
        3 pcs of AA alkaline batteries for power supply
         
    IV. Peripheral configuration of the product
        Industrial test conductor: 1 pair
    User’s Manual: 1 manual
    AA alkaline battery: 3 pcs
    Graphic carton: 1 item
    Fuse: 2 items
    
    
  