10000G High Acceleration Shock Test System for Electronic Component
Product description
Mechanical Shock Test conforms to such testing specifications as GB/T2423-2008, GJB150, GJB360, GJB548, GJB1217, UN38.3, MIL-STD-202F, IEC-68-2-27, MIL-STD-810F, MIL-STD-883E, etc.
Important Features and Benefits
- Lifting mechanism is a precision screw. It is driven by a precision motor, and guided by four precision guide columns to ensure that the platform rise and fall smoothly. Precise shock data accuracy is ensured.
- The shock base adopts the structural design of the airbag + shock absorber damper, which does not affect the floor structure during impact.
- The machine base is designed without resonance and the impact data is accurate
- The use of gas-liquid pressure brake friction friction brake mechanism, no secondary impact function
- Equipped with pressure storage tank to ensure the stability of the brake mechanism and ensure the integrity of the test data
- Single-channel data measurement acquisition, acceleration data measurement, storage, report printing, data callback, database management and other functions
| Main parameters of the shock tester |
| Operating platform | 200 × 200 mm |
| Max. load | 10 KG |
| Peak acceleration | 200-100000m/s2 (200 -10000G) |
| Pulse duration | 0.2~18ms (Half sine wave) |
| Equipment dimensions | 770×670×2750mm |
| Equipment weight | 810 kg |
| Dual Mass Shock Amplifier |
| Table size | 80x150mm |
| Max. load | 2 kg |
| Peak acceleration | 30000G |
| Pulse duration | 0.06—0.5ms |
| Data analysis and acquisition systems |
| Input channels | 4 channels |
| Sampling frequency | 1MHz |
| Coupled mode | AC,DC,IEPE |
| ADC resolution | 16 bits |
| Dynamic range | >80dB |
| harmonic distortion | <85dB |
| Signal to Noise Ratio | >70dB |
| Pulse duration | Less than 0.02ms |
| Acceleration range | Up to 100,000gn |
| External trigger | support |
| Interface | USB2.0 |
| Operating system | Win10 |
| Type | Shock acceleration sensors |
| Model | 3200B2T |
| Output mode | Charge type |
| Sensitivity | 0.05 mV/g±25% |
| Frequency range | 0.5 to 20K Hz frequency range (±10%) |
| Acceleration range | 50000G |
| Operating environment | -51 to +121℃ |
| Other information |
| Power supply | AC, three phase, 380V±10% 60Hz 5KVA |
| Compressed air | 0.5—0.7MPa |
| Applicable standards | GB2423.5, GJB150.18, GJB360.23,UN38.3,IEC68-2-27, MIL—STD202F, MIL-STD810B, GB/T18287, etc. |
Customer Services
Presales:
- Technical consultation: test method, laboratory planning and suggestion.
- Equipment selection: selection scheme, FAQ.
- Product testing scheme.
In-Sales:
- Customer communication and progress report.
- Guidance for pre-installation preparation, equipment commissioning and test run.
- Calibration (when Third Party’s verification is required).
After-Sales:
- Technical training: operation of equipment, daily maintenance, common fault diagnosis, and troubleshooting.
- Scheduled on-site service: Detection of problem as soon as possible in order to eliminate equipment and anthropogenic hazards. This is to ensure long term and stable equipment operation as well as delivery of latest technical information.
- Technical support: special paid services are provided according to customer’s needs.