22KW 30KW 37KW 45KW VFD Variable Frequency Drive 3 Phase Vector Control
22KW 30KW 37KW 45KW VFD Frequency Inverter 3 Phase Support Spanish Russian
Product Features of Three Phase VFD
Tension control and torque mode control
Up to 200% starting torque at Ohz
 Asynchronous motor control
 Comparator and logic unit/controller
Sleeping function
Virtual DI function
Programmable delay unit
 Motor Auto-tune (static and dynamic)
 2 motor parameter groups
 DC Injection brakingLCD keypad and shuttle keypad optional
 Integral brake chopper (<30kW)
 DC reacotor 18.5KW & above optional
 2 PID Control optional
 Energy saving function
 Modbus RTU/RS485 built in
 PC Tool Software
 CANopen card optional
 Profinet card optional
 More compact to save space
 Independent dust design
IO exentsional card
Multiple PG card
Technical Specifications of 3 Phase VFD
|  			 Item  |  			 			 Specification  |  		|
|  			 Input  |  			 			 Input Voltage  |  			 			 1phase/3phase 220V:200V~240V 3 phase 380V-480V:380V~480V  |  		
|  			 Allowed Voltage fluctuation range  |  			 			 -15%~10%  |  		|
|  			 Input frequency  |  			 			 50Hz / 60Hz,fluctuation less than 5%  |  		|
|  			 Output  |  			 			 Output Voltage  |  			 			 3phase:0~input voltage  |  		
|  			 Overload capacity  |  			 			 General purpose application:60S for 150% of the rated current Light load application:60S for 120% of the rated current  |  		|
|  			 Control  |  			 			 Control mode  |  			 			 V/f control Sensorless flux vector control without PG card(SVC) Sensor speed flux vector control with PG card (VC)  |  		
|  			 Operating mode  |  			 			 Speed control,Torque control(SVC and VC)  |  		|
|  			 Speed range  |  			 			 1:100 (V/f) 1:200( SVC) 1:1000 (VC)  |  		|
|  			 Speed control accuracy  |  			 			 ±0.5% (V/f) ±0.2% (SVC) ±0.02% (VC)  |  		|
|  			 Speed response  |  			 			 5Hz(V/f) 20Hz(SVC) 50Hz(VC)  |  		|
|  			 Frequency range  |  			 			 0.00~600.00Hz(V/f) 0.00~200.00Hz(SVC) 0.00~400.00Hz(VC)  |  		|
|  			 Input frequency resolution  |  			 			 Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.1%  |  		|
|  			 Startup torque  |  			 			 150%/0.5Hz(V/f) 180%/0.25Hz(SVC) 200%/0Hz(VC)  |  		|
|  			 Torque control accuracy  |  			 			 SVC:within 5Hz10%,above 5Hz5% VC:3.0%  |  		|
|  			 V/f curve  |  			 			 V / f curve type: straight line, multi point, power function, V / f separation; Torque boost support: Automatic torque boost (factory setting), manual torque boost  |  		|
|  			 Frequency giving ramp  |  			 			 Support linear and S curve acceleration and deceleration; 4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s  |  		|
|  			 DC bus voltage control  |  			 			 Over-voltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault; 
 Under-voltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure 
 VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip; Vdc Min control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump under-voltage fault  |  		|
|  			 Carrier frequency  |  			 			 1kHz~12kHz(Varies depending on the type)  |  		|
|  			 Startup method  |  			 			 Direct start (can be superimposed DC brake); speed tracking start  |  		|
|  			 Stop method  |  			 			 Deceleration stop (can be superimposed DC braking); free to stop  |  		|
|  			 Main control function  |  			 			 Jog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN  |  		|
|  			 Function  |  			 			 Keypad  |  			 			 LED Digital keyboard and LCD keypad(option)  |  		
|  			 Communication  |  			 			 Standard: MODBUS communication CAN OPEN AND PROFINET( IN DEVELOPMENT)  |  		|
|  			 PG card  |  			 			 Incremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card  |  		|
|  			 Input terminal  |  			 			 Standard: 5 digital input terminals, one of which supports high-speed pulse input up to 50kHz; 2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input; Option card: 4 digital input terminals 2 analog input terminals.support-10V-+10V voltage input  |  		|
|  			 Output terminal  |  			 			 standard: 1 digital output terminal; 1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output; 1 relay output terminal(second relay is an option ) 2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output; Option card: 4 digital output terminals  |  		|
|  			 Protection  |  			 			 Refer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function  |  		|
|  			 Environment  |  			 			 Installation location  |  			 			 Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.  |  		
|  			 Altitude  |  			 			 0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m  |  		|
|  			 Ambient temperature  |  			 			 -10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C  |  		|
|  			 Humidity  |  			 			 Less than 95%RH, without condensing  |  		|
|  			 Vibration  |  			 			 Less than 5.9 m/s2 (0.6 g)  |  		|
|  			 Storage temperature  |  			 			 -20°C ~ +60°C  |  		|
|  			 Others  |  			 			 Installation  |  			 			 Wall-mounted, floor-controlled cabinet, transmural  |  		
|  			 Protection level  |  			 			 IP20  |  		|
|  			 cooling method  |  			 			 Forced air cooling  |  		|
|  			 EMC  |  			 			 CE ROHS  |  			 			 Internal EMC filter Complies with EN61800-3 Category C3 3rd Environment  |  		

Product Application


FAQ:
1. What voltage range can you support?
Single-phase 220v input, single-phase 220v output;
 Single-phase 220v input, three-phase 220v output;
 Three-phase 220v input, three-phase 220v output;
 Single-phase 220v input, three-phase 380v output;
2. What is the standard of package?
Below 37kw, it's carton package; 45kw and above, it's wooden package.
3. Do you accept OEM business?