The components of a BTMS primarily include:
Here is some reference data for the BTMS:
|
Unit Model
|
NBSLJZ-03-01
|
|
Rated cooling capacity (kw)
|
3.5
|
|
Low-voltage power demand
|
450W
|
|
High voltage power supply
|
DC400V-DC750V
|
|
Low voltage power supply
|
DC24V(18V-32V)
|
|
Built in water pump
|
>20L/min @110 KPa
|
|
Control power supply
|
DC24V battery provides on/off signal
|
|
Protection level
|
IPX7
|
|
Refrigerant
|
R134a
|
|
Type of secondary refrigerant
|
50%VV Ethylene glycol aqueous solution
|
|
Dimensions
|
530(L)*446(W)*365(H)
|
|
Unit fixed point
|
Φ12 holes *4
|
|
Joint
|
Inlet and outlet water pipeΦ25
|
|
Connector
|
can be configured according to customer needs
|
|
Low voltage power
|
24V 450W
|
|
Unit Model
|
NBSLJZ-05-01
|
|
Rated cooling capacity (kw)
|
5
|
|
Heating capacity
|
6-14kw(Optional)
|
|
High voltage power supply
|
Rated voltage 320VDC (220~450 VDC)
|
|
Low voltage power supply
|
DC24V(18V-32V)
|
|
Built in water pump
|
11m&1800l/h
|
|
Control power supply
|
DC24V battery provides on/off signal
|
|
Protection level
|
IPX7
|
|
Refrigerant
|
R134a
|
|
Type of secondary refrigerant
|
50%VV Ethylene glycol aqueous solution
|
|
Dimensions
|
635(L)*530(W)*380(H)
|
|
Unit fixed point
|
569mm*369mm Φ12holes *4
|
|
Joint
|
Inlet and outlet water pipeΦ25
|
|
Connector
|
can be configured according to customer needs
|
|
Low voltage power
|
24V 600W
|
|
Unit Model
|
NBSLJZ-08-01
|
|
Rated cooling capacity (kw)
|
8
|
|
Low-voltage power demand
|
600W
|
|
High voltage power supply
|
DC400V-DC750
|
|
Built in water pump
|
20m&2000l/h
|
|
Control power supply
|
DC24V battery provides on/off signal
|
|
Protection level
|
IPX7
|
|
Refrigerant
|
134a/R407C
|
|
Type of secondary refrigerant
|
50%VV Ethylene glycol aqueous solution
|
|
Dimensions
|
820(L)*575(W)*285(H)
|
|
Unit fixed point
|
495mm*320mm Φ12holes *6
|
|
Joint
|
Inlet and outlet water pipeΦ25(Reserved overflow pipeΦ8)
|
|
Connector
|
can be configured according to customer needs
|
|
Electronic control
|
Four in one/Three in one integrated
|
|
Unit Model
|
NBSLJZ-10-01
|
|
Rated cooling capacity(kw)
|
10
|
|
Heating capacity
|
24KW(Optional)
|
|
High voltage power supply
|
640VDC (400~750 VDC)
|
|
Built in water pump
|
17.5m&2880l/h
|
|
Control power supply
|
DC24V battery provides on/off signal
|
|
Protection level
|
IPX7
|
|
Refrigerant
|
134a
|
|
Type of secondary refrigerant
|
50%VV Ethylene glycol aqueous solution
|
|
Dimensions
|
960(L)*603(W)*291(H)
|
|
Unit fixed point
|
521mm*320mm Φ12holes *6
|
|
Joint
|
Inlet and outlet water pipeΦ25(Reserved overflow pipeΦ8)
|
|
Connector
|
can be configured according to customer needs
|
|
Electronic control
|
Four in one/Three in one integrated
|
|
Unit Model
|
NBSLJZ-13-01
|
|
Rated cooling capacity (kw)
|
12
|
|
Heating capacity(kw)
|
Optional24Kw-30Kw
|
|
High voltage power supply
|
DC400V-DC750V
|
|
Low voltage power supply range
|
DC 18~32V
|
|
Energy efficiency ratio
|
2.0
|
|
Protection level
|
IPX7
|
|
Refrigerant
|
134a/R407C
|
|
Type of secondary refrigerant
|
50%/50% Ethylene glycol aqueous solution
|
|
Dimensions
|
L1370×W1030×H285 mm
|
|
Unit fixed point
|
Φ12holes *8
|
|
Joint
|
Inlet and outlet water pipeΦ25
|
|
Connector
|
can be configured according to customer needs
|
|
Electronic control
|
Four in one/Three in one integrated
|