Process Connection | Flange/material 304 stainless steel, PP |
Antenna profile | PTFE |
Shell | Cast aluminum/stainless steel/plastic ABS |
Sealing between shell and shell cover | silicon rubber |
Shell Window | polycarbonate |
Grounding terminal | Stainless steel |
Power supply voltage | | | ||
| Four wire system | (12-24) VDC | ||
| | Power consumption max80mADC24V/2W | ||
| | Allow ripple<100Hz Us | ||
| | (100-100K) Hz Uss<10mV | ||
| Dual chamber housing | (198-242) V AC four wire system | ||
| | 110V AC four wire system |
Cable parameters | | | ||
| Cable entry/plug | 1 M 20xl.5 cable entry | ||
| | 1 blind plug M20xl. 5 | ||
| Wiring terminals | Wire cross-section 2.5mm ² |
Output parameters | | | ||
output signal | | (4-20) mA/RS 485 Modbus | ||
resolving power | | 1mm | ||
Fault signal | | The current output remains unchanged; 20. 5mA; 22mA; 3.9mA | ||
Integral time | | (0-20) s, adjustable | ||
Blind spot | | 0.08m/0.2m/0.3m | ||
Maximum measurement distance | | 150 meters | ||
Measurement interval | | Approximately 1 second (depending on parameter settings) | ||
Adjust time | | Approximately 1 second (depending on parameter settings) | ||
Working storage and transportation temperature | | (-40~80) ℃ | ||
relative humidity | | ˂ 95% | ||
pressure | | Max. 2.5MPa | ||
Seismic resistance | | Mechanical vibration 10m/s ² , (10-150) Hz |