Specifications
Certification :
CB, ISO
Setpoint Resolution :
0.5°C / 1°C
Pump Head (Standard) :
1,200 mm
Bus Communication :
HyperLink, up to 2,000 m
Place of Origin :
China
Capacity Range :
2.2–14.0 kW
Power Architecture :
Independent supply (partial shutdown tolerant)
Product Name :
Two-Way Cassette
System Compatibility :
Heat pump VRF / Heat recovery VRF
Brand Name :
OEM; MIDEA
Description
Two-Way Cassette VRF CE Certified Multi-Zone Control Commercial Building HVAC
Symmetrical Air Distribution from a Single Pocket

Halving equipment count while doubling coverage uniformity, the Midea V8 Two-Way Cassette eliminates the need for specifying two single-direction units at opposite ends of corridors. This innovative solution features two opposing discharge ports that generate mirror-image airflow patterns, effectively blanketing elongated zones from a single installation point. The result is significant savings in hardware costs, reduced wiring complexity, fewer drain connections, and simplified commissioning processes.

Core Highlights
  • Opposing Dual-Port Air Distribution: Two discharge openings face 180° apart, producing symmetrical throw that reaches both ends of linear spaces simultaneously, halving required unit count in corridor applications.
  • Continuous Dew-Point Surveillance: Advanced algorithmic anti-sweat logic cross-references humidity, supply-air temperature, and grille surface temperature to prevent condensation before it becomes visible.
  • Digitally-Monitored Drainage with Preemptive Alerts: Real-time RPM and flow tracking enables pump controller to flag anomalies before they escalate into water damage events.
  • Generous 1,200 mm Pump Lift: Standard high-lift drainage handles aggressive pipe slopes and extended horizontal routing through dense plenum obstructions.
  • Half-Degree Thermal Resolution: Precise 0.5°C / 1°C setpoint granularity allows optimal balance between comfort and energy consumption.
  • Automatic Mode Transition: Cooling-to-heating handoff occurs without manual intervention, eliminating seasonal changeover visits.
Application Scenarios
Scenario Description
Hotel Corridors One unit replaces two single-throw units per corridor bay; reduced pipe runs lower hospitality HVAC installation cost
Shopping Mall Arcades Symmetrical throw reaches opposing storefronts uniformly from central ceiling position
Hospital Circulation Paths Balanced bilateral airflow avoids uncomfortable cross-drafts in patient walking zones
Museum Gallery Routes Consistent temperature along exhibition sightlines protects sensitive artifacts from thermal fluctuation
School & University Library Aisles Even coverage across long rectangular reading areas eliminates localized comfort complaints
Certifications & Standards
  • CE Certified – Full European conformity compliance for unrestricted EU market access
  • Eurovent – Certified performance data for European market compliance
  • TÜV SÜD – Third-party verified safety and performance standards
  • SASO Certified – Saudi Arabian standards approval
  • ESMA Approved – UAE standardization compliance
  • GCC Standard Compliant – Gulf region deployment ready
  • ISO 9001 – Quality management ensuring consistent manufacturing quality
  • ISO 14001 – Environmental management system for responsible production
  • ISO 45001 – Occupational health and safety standards across product lifecycle
Technical Specifications
Parameter Two-Way Cassette
Capacity Range 2.2-14.0 kW
Air Distribution Dual-direction opposing throw
Pump Head (Standard) 1,200 mm
Setpoint Resolution 0.5°C / 1°C
Drive Architecture Full-DC inverter
Pump Intelligence Real-time RPM & flow monitoring
Sweat Prevention Continuous dew-point evaluation
Bus Communication HyperLink, up to 2,000 m
Power Architecture Independent supply (partial shutdown tolerant)
System Compatibility Heat pump VRF / Heat recovery VRF
BMS Integration Modbus RTU / BACnet compatible
Available Capacities & Pairing

Compatible with all V8 series outdoor units via HyperLink arbitrary topology communication. Full BMS integration via Modbus RTU and BACnet protocols enables centralized building automation system management.

Send your message to this supplier
Send Now

Two-Way Cassette VRF CE Certified Multi-Zone Control Commercial Building HVAC Dual-Throw Ceiling Cassette That Cuts Unit Count in Corridors

Ask Latest Price
Certification :
CB, ISO
Setpoint Resolution :
0.5°C / 1°C
Pump Head (Standard) :
1,200 mm
Bus Communication :
HyperLink, up to 2,000 m
Place of Origin :
China
Capacity Range :
2.2–14.0 kW
Contact Supplier
Two-Way Cassette VRF CE Certified Multi-Zone Control Commercial Building HVAC Dual-Throw Ceiling Cassette That Cuts Unit Count in Corridors
Two-Way Cassette VRF CE Certified Multi-Zone Control Commercial Building HVAC Dual-Throw Ceiling Cassette That Cuts Unit Count in Corridors

Henan Hongtai HVAC Equipment Co., Ltd.

Verified Supplier
3 Years
henan, zhengzhou
Since 2023
Business Type :
Manufacturer, Distributor/Wholesaler, Agent, Exporter, Trading Company, Seller
Total Annual :
6,000,000-8,000,000
Employee Number :
100~150
Certification Level :
Verified Supplier
Contact Supplier