Specifications
Brand Name :
YunYi
Model Number :
YUNYI-ZFG
Certification :
CE,ROHS
Place of Origin :
China
MOQ :
1 piece
Price :
USD1250-USD444 PER PIECE
Payment Terms :
D/A, D/P, T/T, Western Union
Supply Ability :
1000 Piece/Pieces per Month
Delivery Time :
10DAYS
Packaging Details :
Standard carton box/wooden cases
Name :
Electromagnetic flow meter for Sewage Pipeline Cement Slurry and Urban water use
Pipe size :
DN10 ~ DN300
Lining material :
Rubber; PTFE, F46
Range ratio :
150: 1
Repeatability error :
± 0.1% of the measured value
Accuracy :
0.5%FS
Flow rate range :
0.1-15m / s
Conductivity range :
measured fluid conductivity ≥ 5μs / cm
Output :
RS485/4-20mA/Pulse
Description

Description Electromagnetic flow meter for Sewage Pipeline Cement Slurry and Urban water use

The intelligent electromagnetic flowmeter consists of two main components: a sensor and a converter. Its working principle is based on Faraday's law of electromagnetic induction.

  • Measures the volumetric flow of conductive liquids (conductivity > 5μS/cm).
  • Capable of measuring homogeneous liquid - solid two - phase flows, like acid/alkali suspensions, corrosive liquids, and slurries.
  • Widely used in industries such as petroleum, chemical, metallurgy, textile, and environmental protection.
  • Also applied in municipal administration, water conservancy construction, and river dredging.

Detailed Images

Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use

Specification Sewage pipeline cement slurry flowmeter electromagnetic flowmeter with sand

Conductivity Range The measured fluid condutivity≥5μs/cm
Load Resistance 0 ~ 10mA 0 ~ 1.5KΩ
Current Output 4 ~ 20mA 0 ~ 750KΩ
Digital Frequency Output Transistor output frequency limit can be set with optical isolation within 1~5000Hz bidirectional open-collector output. External power supply is turned ≤35V maximum collector current of 250mA
Power Supply AC 220V Or DC 24V
Length Of Straight Pipe Requirements Up Stream≥5DN, Down Stream≥2DN
Connection are used between the meter and piping flange connection, flange dimensions shall comply with the provisions of GB11988
Explosion Levels Exd II BT4
Protection Class IP65, Special Order up to IP68
Ambient Temperature -25℃ ~ +60℃
Relative Humidity 5% ~ 95%
Total Power Consumption Less Than 20W

Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use

Dimension

Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use

Feature

  1. Robust Structure: The sensor features an all - welded design, ensuring excellent sealing and durability.
  2. Comprehensive Parameter Monitoring: Records physical parameters of measured media, including pressure, temperature, density, and viscosity.
  3. Advanced Processing: Equipped with a 16 - bit embedded microcontroller for rapid, high - precision calculations.
  4. Dual - Flow Functionality: Measures both forward and reverse flows, displaying flow rates, percentages, and velocities.
  5. Enhanced Performance: Incorporates conductivity measurement to check sensor - controller status; offers digital content processing for strong anti - interference and reliable, accurate measurements.
  6. Reliable Power Supply: Utilizes a low EMI switch power supply, providing good EMC performance and stable operation under wide voltage fluctuations.
  7. Self - Diagnosis: Capable of self - diagnosing issues and providing troubleshooting guidance.
  8. Customizable Options: Available in explosion - proof types to meet diverse application requirements.

The sensor adopts overall welding structure, good sealing

Selection

Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use

Installation:

Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use

Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use

Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use

Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use

Send your message to this supplier
Send Now

Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use

Ask Latest Price
Watch Video
Brand Name :
YunYi
Model Number :
YUNYI-ZFG
Certification :
CE,ROHS
Place of Origin :
China
MOQ :
1 piece
Price :
USD1250-USD444 PER PIECE
Contact Supplier
video
Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use
Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use
Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use
Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use
Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use
Electromagnetic Flow Meter For Sewage Pipeline Cement Slurry And Urban Water Use

Xi'an Yunyi Instrument Co., Ltd

Verified Supplier
5 Years
Since 2007
Business Type :
Manufacturer, Exporter
Total Annual :
1000000-2000000
Employee Number :
150~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement