Typical application scenarios
Chemical/petrochemical: monitoring acid-base concentration and reaction liquid density.
Food and beverage: sugar content and alcohol content detection.
Pharmaceutical: liquid medicine ratio control.
Environmental protection: sludge concentration monitoring in wastewater treatment.
| Measure range | 0–3g/cm3 (0 – 3000 kg/m3) |
| Accuracy | ±0.001g /cc (±1 kg/m3) |
| Operating temperature | -50℃ ~ +200℃ |
| Max work temperature | 20MPa |
| Fluid viscosity range | 0 – 20000 cP |
| Temperature coefficient | 0.1 kg/m3/℃ |
| Pressure influence | Can be ignored |
| Built in temperature sensor | PT100 |
| Wetted part material | Stainless steel, Hastelloy C22, manganese alloy 400, titanium alloy, etc. |
| Fork body coating | Standard type, PTFE or electrolytic polishing |
| Power supply | 20–28 VDC,35–45 mA |
| Analog signal output | 4-20 mA, isolated, non self powered |
| Output accuracy(20℃) | ±0.1%FS, ±0.05%FS |
| Output repeatability (-40~ 85℃) | ± 0.05% FS |
| Process connection | 1.5"NPT threaded connections; din 50 PN40 and PN100 flange connections; |
| Protection | IP65 |