High Current Square Shaped Thermal Cutoff Fuse Links 40A 50A 250V 150C 190C
Scope
The specification is for Y series thermal link (hereinafter referred to as the temperature fuse).
Structure
Thermal link is made of plastic shell, melting point alloy wire, special resin, copper pins, and seal resin.
Appearance and specification
The printing signs must be clear; sealing resin should be filled with mouth and can be filled with; the tin layer of the pin is good; the phenomenon of oxidant black dot damage; the shell has no broken damage, perforation, etc.
TYPE | Rated Function Temperature Tf(℃) | Hold Temperature Tc(℃) | Max temperature Tm(℃) | Actual Action Temperature(℃) | Rated Voltage Ur(V) | Rated Current Ir(A) |
Y85 | 185 | 140 | 210 | 182±3 | 250 | 40/50 |
Y90 | 190 | 140 | 215 | 185±5 | 250 | 40/50 |