Description
UV Weathering Resistance Test Chamber meet GB/T14522-93 the method that mechanical products be accelerated tested in a artificial way with plastic, paint, rubber meterial, GB/T2424.14-1995 basic environmental testing procedures of electrical and electronic products, American material test institute ASTMG53-84 test method that non-metallic material exposed to fluorescent UV condensation.
Specifications
|
Model |
UV-260 |
UV-SI-260 |
|
Internal dimensions (mm) |
450*1170*500 |
450*1170*500 |
|
Overall dimensions (mm) |
680*1300*1500 |
680*1300*1500 |
|
Capacity of test specimens |
48 pieces Individual specimen size is 75mm * 150mm |
48 pieces Individual specimen size is 75mm *150mm |
|
Controller |
Programmable color display touch screen controller |
Programmable color display touch screen controller |
|
Temperature range |
Ambient~90℃ ±2℃ |
Ambient~90℃ ±2℃ |
|
Humidity range |
≥95%R.H ±2%R.H |
≥95%R.H ±2%R.H |
|
Black Panel Temperature |
BPT 30~80℃ |
BPT 30~80℃ |
|
Irradiation Source |
Fluorescent UV lamps (8) - 40 W |
Fluorescent UV lamps (8) - 40 W |
|
UV wavelength |
290 ~ 400nm |
290 ~ 400nm |
|
Irradiance Control |
N/A |
0.3 ~ 20 W/㎡(340 nm / 313 nm) |
|
Water Spray |
Spraying water |
Spraying water |
|
Distance of Specimen and lamp |
50mm |
50mm |
|
Nominal power |
5000W |
5500W |
|
Power Supply |
380V 50HZ |
380V 50HZ |
Details
![]() |
![]() |
| UV lamp | Black Panel Thermometer |
Features
● Frequency conversion control of wind speed. Accelerated Weathering Tester
● Adopts international brand of imported parts for cooling system to improve operation reliability.
● Touch screen controller, friendly Man-Machine interface and safety device to ensure simple operation and easy maintenance.
● Control System: High precision temperature control instrument,
● Programmable time controller (set test time, illumination time, condensation time, spraying time )
● Electronic Components: Adopt product of national joint venture company
● UV Resistance equpiment main configuration: Temperature controller , time controller, illumination time accumulator, inflow magnetic valve, UV lamps.
Test Standard
●ISO 4892-3:2016 Plastics — Methods of exposure to laboratory light sources — Part 3: Fluorescent UV lamps
●EN 927-6 Paints and varnishes – Coating materials and coating systems for exterior wood – Part 6: Exposure of wood coatings to artificial weathering using fluorescent UV lamps and water
●ASTM G154 – Standard Practice for Operating Fluorescent Ultraviolet (UV) Lamp Apparatus for Exposure of Nonmetallic Materials
![]() |
![]() |