Specifications
Transfer Time :
Zero
Output :
3 x 380VAC/400VAC /415VAC(3Ph + N)
Precision :
Stationary: ±1% Transitory: ±5% (load variations 100-0-100%)
Current Limit :
High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit
Frequency :
50Hz&60Hz
Brand Name :
BLAZING POWER
Model Number :
W-20KL
Certification :
CE
Place of Origin :
China
MOQ :
1 Unit
Price :
2000-5000$/Unit
Payment Terms :
T/T,Western Union,L/C
Supply Ability :
Stock
Delivery Time :
3-5 Days
Packaging Details :
Pallet
Waveform :
Pure Sinewave
Nominal Battery Voltage :
384 VDC (Based on 32pcs batteries)
Charging Current :
Default 10A;
Input :
3 x 380VAC/400VAC (3Ph + N)
Capcity :
20KVA/16KW
Description
Dual-Input Line-Low Frequency UPS 20KVA
Medical Device Dedicated UPS

Designed specifically for medical applications, this UPS system ensures security and stability for critical healthcare equipment.

Security & Stability Features
  • Utilizes microprocessors for fully digital control of all UPS power conversion stages, enhancing system consistency and stability
  • Incorporates controllable rectifier design to significantly improve grid adaptability, ensuring greater safety and reliability for the inverter
  • Features a built-in output isolation transformer to minimize the impact of neutral-to-ground voltage and load harmonic currents on the inverter
  • Independent battery interfaces prevent critical failures caused by installation errors, substantially reducing operational risks
  • Over 90% of components utilize internationally renowned brands, with each unit undergoing 24-hour burn-in testing and validation before shipment
Product Features
  • Double-conversion online design delivers pure sine wave output, providing critical loads with stable voltage and frequency power supply free from grid disturbances
  • During mains failure, the UPS inverts battery energy to the load, ensuring uninterrupted power output
  • High-frequency double-conversion architecture with output isolation transformer and advanced fully digital control technology for stable, clean, and uninterrupted power
  • Diverse communication solutions including MODBUS, RS232, and expandable smart slot for convenient configuration and monitoring
System Architecture

Primary components include rectifier and inverter modules forming double-conversion circuit (AC to DC to AC), plus static bypass, maintenance bypass, and battery charge/discharge circuits. Mains power and bypass switching via thyristors in reverse parallel configuration acting as transfer switches.

Send your message to this supplier
Send Now

Dual Input Low Frequency UPS 10KVA Pure Sinewave Output for Medical Devices

Ask Latest Price
Transfer Time :
Zero
Output :
3 x 380VAC/400VAC /415VAC(3Ph + N)
Precision :
Stationary: ±1% Transitory: ±5% (load variations 100-0-100%)
Current Limit :
High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit
Frequency :
50Hz&60Hz
Brand Name :
BLAZING POWER
Contact Supplier
Dual Input Low Frequency UPS 10KVA Pure Sinewave Output for Medical Devices
Dual Input Low Frequency UPS 10KVA Pure Sinewave Output for Medical Devices

Shenzhen Tafeng Technology Co., Ltd.

Verified Supplier
1 Years
guangdong, shenzhen
Since 2001
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter
Total Annual :
10000000-20000000
Employee Number :
100~500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement