Name plate (Min. order: 1 set)
Working Temperature(℃) (Min. order: 1 set)
Capacity (kg/h) (Min. order: 1 set)
Material (Min. order: 1 set)
Products Description
Main application: Corundum melting furnace, used for melting various corundum, spinel, mullite and other abrasives and refractory materials.
Equipment features: The furnace cover can be unscrewed, and an observation device and water-cooled feeding port are installed on the furnace top. Large cross-section water-cooled cables, hydraulic transmission; Automatic adjustment of electrode lifting. The material of the electrode chuck is chrome copper, and it is clamped with a stainless steel clamping band. The high-voltage electrical control adopts vacuum switch cabinets, which are equipped with complete detection and measurement functions for voltage, current, power and electricity consumption. The electric furnace transformer adopts a low-loss energy-saving transformer. The control of low-voltage electrical appliances adopts a PLC programmable controller. The cooling water system is equipped with pressure and water temperature monitoring, as well as audible and visual alarms. The advanced and complete central centralized control system realizes the integration, intelligence, control, warning and protection system of the production line, ensuring the safe and reliable operation of the production line. It can provide the possibility for the networking of users' data management.
Equipment composition: furnace body, furnace body tilting mechanism, furnace cover, furnace cover lifting and rotating device, electrode lifting device, short network system, transformer, water cooling system, hydraulic system, low-pressure system, high-pressure system, automatic control system, etc.
|
Inner diameter of furnace shell
|
Φ 2500mm
|
|
Furnace shell depth
|
2000mm
|
|
Cone height
|
750mm
|
|
Electrode diameter
|
Φ 200mm
|
|
Diameter of electrode distribution circle
|
Φ 650mm
|
|
Electrode stroke
|
1700mm
|
|
Electrode lifting speed
|
2-2.5m/min
|
|
Rated capacity of transformer
|
1000KVA;
(Long term overload 20%, short-term overload 30%)
|
|
Primary voltage of transformer
|
22KV;
|
|
Secondary voltage
|
90~150V
(seven levels) no-load electric voltage regulation
90~130 constant current;130~150V constant power
|
|
Primary current
|
26.275A
|
|
Secondary current
|
4446 A (130V)
|
|
Cooling method
|
OFWF (strong oil water cooling)
|
1. Customize according to your requirements and provide you with an effective quotation.
2. We have professional engineers to design the plan for you.
3. Our team will provide professional advice and help for your whole project.
4. Our factory is always ready to welcome field visits.
5. Ensure high quality after-sales service.