Main features
●Single jet, dry disc, magnetic drive, anti-magnetic or non-magnetic.
●Suitable for cold (30°C) and hot water (90°C), sizes Ø 15 to 25 mm (1/" – 1").
●Body material: brass, nickel-plated
●Measurement accuracy in accordance with ISO 4064 class B standard Internal adjustment device
Main technical parameters
| Gauge sizeDia DN (mm) |
Type | Qs Overload flow |
Qp Rated flow |
Qt Transition flow |
Qminimum flow | Minimum pulse quantity | Maximum pulse quantity |
| m3/h | 1/h | m3 | |||||
| 13 | A | 3 | 1.5 | 150 | 60 | 0.0001 | 99999 |
| B | 120 | 30 | |||||
| 20 | A | 5 | 2.5 | 250 | 100 | 0.0001 | 99999 |
| B | 200 | 50 | |||||
| 25 | A | 7 | 3.5 | 350 | 140 | 0.0001 | 99999 |
| B | 280 | 70 | |||||
Working conditions
Cold water meter water temperature: ≤50°C
Water temperature: ≤90°C hot water meter
Working pressure ≤1.0 MPa
The flow resistance advantage compared to volumetric water meters - smaller head loss, energy saving and consumption reduction.
The initial investment advantage compared to smart water meters - the lowest initial cost in scenarios where remote functionality is not required.
Highly mature technology - tested by the market, it is one of the classic mechanical water meter technologies.
No need for external energy - relying on natural water flow to drive, green and environmentally friendly.