|  			 Pneumatic Ventilator  			 |  			 			 R30  			 |  		
 		 			|  			 l Display  			l Respiratory mode  			l Graphical display  			l Battery  			l Data communication port  			 |  			 			 l 10.4”, TFT display, with touch screen  			l VCV, PCV, SIMV-VC, SIMV-P, CPAP/PSV, BACKUP (Optional:Duophasic / APRV, NIV )  			l P-T, F-T, V-T(Optional: CO2-time, pulserate-time)  			l loop: P-V, F-V  			l NI-MH battery, >120mins  			l RS232, VGA, USB, Remote alarm  			 |  		
 		 			|  			 Operating Conditions  			 |  			 			    			 |  			 			    			 |  		
 		 			|  			 l Gas supply: Air, O2, 280kPa -600kPa (40~87 PSI)  			l Power supply: 100-240V, 50/60Hz  			l Temperature: 10-40℃ (Operation), -20-60℃ (Storage)  			l Relative humidity: 5-95%, non-condensing (Operation)  			≤95%, non-condensing (Storage)  			l Atmospheric pressure (Operation & Storage): 500hPa-1060hPa  			l Dimensions (H×W×D):  			Ventilator: 455mm x 400mm x 300mm  			Trolley: 565mm X 535mmX 910mm  			l Weight:  			Ventilator: 12.5 kg  			Trolley: 20 kg  			 |  			 			    			 |  			 			    			 |  		
 		 			|  			 Standards  			 |  			 			    			 |  		
 		 			|  			 IEC 60601-1, IEC 60601-1-2, IEC 60601-1-8, IEC 60601-2-12  			 |  			 			    			 |  		
 		 			|  			 Alarm  			 |  			 			 Upper limit  			 |  			 			 Lower limit  			 |  			 			    			 |  		
 		 			|  			 Tidal volume  			Minute volume  			Oxygen concentration  			Airway pressure  			Respiratory frequency  			SPO2  			ETCO2  			Pulse rate  			 |  			 			 20~3000 mL  			1~99 L  			22~100%, OFF  			1~99 cmH2O  			1~120 bpm  			50~99%, OFF  			0.1~13.3 kPa  			31~250 bpm  			 |  			 			 OFF,20~2999 mL  			0~98 L  			20~100%  			0~98 cmH2O  			0~99 bpm  			49~99%  			0~13.2 kPa  			30~249 bpm  			 |  			 			    			 |  		
 		 			|  			    			 |  			 			    			 |  			 			    			 |  			 			    			 |  		
 		 			|  			 Circuit occlusion  			Apnea alarm  			O2 SUPPLY DOWN alarm  			Mains failure alarm  			Battery power low alarm  			Battery discharged alarm  			Alarm silence  			 |  			 			 (PEEP+15) cmH2O, 15s  			15~60s  			< 280 kPa  			Automatically switch  			< 10 min  			< 5 min  			≤120 s  			 |  			 			    			 |  		
 		 			|  			 Auxiliary O2  			 |  			 			 Auxiliary O2 Flow meter(O2: 0~15LPM) (Optional)  			 |  		
 		 			|  			 ACGO  			 |  			 			 Yes  			 |  		
 		 			|  			 O2 Flush  			 |  			 			 25-75L/Min  			 |  		
 		 			|  			 Battery  			 |  			 			 NI-MH battery build in.  			>90mins  			 |  		
 		 			|  			 Yoke  			 |  			 			 2 (O2, N2O) (Optional)  			 |  		
 		 			|  			 Gas Cylinder  			 |  			 			 O2, N2O (Optional)  			 |  		
 		 			|  			 Cycle Absorber  			 |  			 			 Intergrade, bypass Design, heating system.  			 |  		
 		 			|  			 Setting  			 |  			 			 Parameter  			 |  			 			 Monitoring  			 |  			 			 Parameter  			 |  		
 		 			|  			 Tidal volume (optional 20ml)  			Respiratory frequency  			Inspiratory time  			Breath-hold time  			Pressure triggering  			Flowrate triggering  			PEEP  			Pressure support  			Pressure control  			High pressure level  			Low pressure level  			Oxygen concentration  			100% O2  			Thigh (optional)  			freeze  			 |  			 			 20~2500mL  			1~120 bpm  			0.1~12 s  			0~50%  			-20cmH2O~PEEP 0  			0.5~20 L/min  			0~50 cmH2O  			0~80 cmH2O  			5~80 cmH2O  			5~80 cmH2O  			0~50 cmH2O  			21~100%  			2min  			0.1~30s  			Yes  			 |  			 			 Inspiratory tidal volume  			Expiratory tidal volume  			Minute volume  			Spontaneous minute volume  			Spontaneous respiration frequency  			PEEP  			Airway peak pressure  			Mean airway pressure  			Inspiratory platform pressure  			Minimum airway pressure  			Inhaled oxygen concentration  			Airway resistance  			RSBI  			SPO2 (Optional)  			Pulse Rate (Optional)  			EtCO2 (Optional)  			 |  			 			 0~4000 mL  			0~4000 mL  			0~99 L  			0~99 L  			0~120 bpm  			0~100 cmH2O  			0~100 cmH2O  			0~100 cmH2O  			0~100 cmH2O  			-20~100 cmH2O  			15% ~100 %  			0~600 cmH2O/(L/S)  			0 ~ 9999 bpm/L  			70 ~ 100 %  			30~250 bpm  			0 ~ 100 mmHg  			 |