IEC 62133-2 Temperature Controlled Type External Short Circuit Tester 408L Current 1000A
Product information:
It is conforms to the standard of IEC 60335-1:2021 Annex B, UN38.3 clause 4.5 Test T.5, UL 1642, IEC 62619:2017 clause 7.2.1, IEC62133-1:2017 clause 7.3.2 , IEC62133-2:2017 clause 7.3.1 and 7.3.2 , IEC62133:2014 clause 7.3.2,8.3.1, 8.3.2, IEC60086-4 clause 6.5.1, IEC60086-4 clause 6.5.8 6.5.9 , and so on.
Technical Parameters:
Name | Parameters |
Model | SN551-408L1000A |
Max. load current | 1000A |
DC response time | ≤5μs |
Built-in resistor | 10±0.2mΩ |
Inner chamber size | W700*700H*D600mm |
Control method | PLC and Touch screen |
Inner box material | Stainless steel |
Sealing strip | Corrosion-resistant silicone. |
Temperature control | Normal temperature RT+10℃~100℃ (can be preset) Temperature rise rate 3±1℃/min Temperature dial 0.5℃ Temperature uniformity: ±2℃ |
Test stop condition | 1) The battery temperature drops to 20% lower than the peak; 2) Short circuit time |
Battery surface temperature | Can monitor temperature changes during battery surface testing |
Sample rack | Stainless steel SUS #201 perforated steel plate storage rack, with a maximum load-bearing capacity of 30KG on a single layer. The height is adjustable at the same time. |
Hall element collects current signal | Hall elements are used to collect the current generated when the short-circuit system is short-circuited, avoiding the generation of contact resistance, and the data transmission is stable and accurate;
|
Lead hole | There is a lead hole with a diameter of 50mm on the left side of the box for test wires to pass through. |
Chamber door | High-strength hinges are used to fix the door, and at least 2 sets of explosion-proof locks can be installed on the door to fix it.
|
Explosion-proof pressure relief device | It has the function of exhaust, explosion-proof and pressure relief. The rear of the protective box has a magnet-adsorbed pressure relief door (200*200mm). When strong airflow impacts, the pressure relief door automatically opens and closes to reduce the impact of the explosion. |
Lighting | The test chamber door is designed with high-brightness LED lighting to make it easy to see the test conditions in the test chamber. |
Smoke exhaust | Powerful smoke exhaust and air induction centrifuge: high temperature resistant, back smoke exhaust port diameter 60mm |
High temperature motor | High-temperature-resistant long-axis motor/370W made in Taiwan for high-temperature boxes, multi-wing wind wheel with large air volume and low noise |
Heater | Fin-type heat pipe nickel-chromium alloy U-shaped high-efficiency heater automatically calculates high-precision PID+SSR control (calculation cycle: 1~4S can be set), so that its heat loss is equivalent to the heating amount, so it is better than traditional ON/OFF Control saves about 10% power |
Thermometer | Made in Taiwan, high precision, DIN specification grade A, ψ4.8mm, SUS #304 stainless steel, PT 100Ω |
Explosion proof chain | The door is equipped with 3 explosion-proof chains to prevent the door from being blown out and injuring people. |
Control panel security design | The control panel is built-in, and the touch screen and buttons will not be mistakenly pressed or collided by external objects or the body. It is safer. |
Tempered glass window | The test chamber door is equipped with a 300*300mm double-layer tempered glass window, which can clearly observe the test conditions in the test chamber. |
Bottom design | There are 4 universal casters for easy movement and transportation. It is also equipped with 4 foot cups for convenient positioning and fixing equipment. |
Explosion-proof lighting design | The door is designed with high-brightness explosion-proof LED lights to illuminate the entire testing space. |
Current acquisition channel | 1 channel |
Current collection range | 0-1000A DC |
Current acquisition accuracy | ±0.5%F.S |
Current acquisition rate | 1 time/S |
Voltage acquisition channel | 1 channel |
Voltage collection range | 0~100V |
Voltage acquisition accuracy | ±0.2%FS |
Voltage acquisition rate | 1 time/S |
Temperature acquisition channel | 1 channel |
Temperature collection range | RT~100℃ |
Temperature collection accuracy | ±2℃ |
Temperature acquisition rate | 1time/S |
Battery surface temperature collection channel | 2 channels -20-800℃ |
Remote control short circuit | Remote control of short circuit test can be achieved |
Chamber external dimensions | Approx. W950 X D950 X H1700mm (Subject to design) |
Chamber weight | Approx.300kg |
Voltage and frequency | AC 220V, 50HZ |
Total power | 3 KW |