Specifications
Brand Name :
SINOMEMB
Model Number :
SNU-HI-1-H60
Certification :
NSF
Place of Origin :
China
MOQ :
5
Packaging Details :
Standard export packaging
Core Components :
MBR
Product name :
hollow fiber ultrafiltration membrane, ultrafiltration system, PVC Hollow fiber UF membrane module
Pore size :
customized., from 1μm to 0.05μm, 0.01micron, 1.0μm, 0.2μm
Usage :
Waste water treatment, , Liquid Filter, remove bacterias, Purification
Module :
Out-inside
Nominal Pore Size :
0.01μm
Size :
225×1708mm
Membrane Material :
PES
Surface Area :
46m2
Description
SNU-HM hollow fiber submerged curtain UF

SNU-HM type hollow fiber submerged curtain UF adopts a special patented technology in the spinning process and adds a reinforced reinforced lining, so it has all the advantages of PVDF material membrane filaments, but also has high strength and toughness. specialty. This feature fundamentally makes up for the biggest shortcoming of the traditional PVDF membrane, which is low in strength, easy to break, and cannot be well adapted to high-intensity aeration environments. It is of great milestone significance for the application of PVDF membrane in the MBR process. At the same time, since the design flux of the SNU-HM hollow fiber submerged curtain UF membrane is generally set to an appropriate value according to different water qualities, its online cleaning cycle is relatively long, about 7 to 17 days.

Membrane element specifications and main performance
model SNU-HM-Ⅰ SNU-HM-Ⅱ
Specifications ( mm ) 630*1500*36 630*2000*36
Membrane inside and outside diameter ( mm ) 1.5/2.6 0.8/1.4
Effective membrane area (㎡) 15 20
Filtration precision (μ m ) 0.05
Membrane material U-PVC/ABS
membrane material Modified PVDF (polyvinylidene fluoride) and PET (polyester) support tubes
Connecting pipe specification Φ32
Water collection method Water catchment at both ends
filter method Submerged Suction Filtration
PH value 2-12
temperature (°C) 10-45
Oil content ( ppm ) <3
Transmembrane pressure TMP (Mpa) 0.02-0.05
Backwash pressure (Mpa) 0.1
Aeration rate ( m³/h ) Air-water ratio 15:1-20:1
Backwash water flux ( L/㎡·h ) 25-50 25-36
Collecting pipe center distance (mm) 1500
Sludge concentration ( ppm ) 4000-12000 3000-10000
Design flux ( L/㎡·h ) 15-25 12-18
Product water quality Turbidity≤0.2NTU, SDI≤3
service life ≥3 years under standard conditions
UF membrane element size
Operation Guide

During the operation of the UF system, it is necessary to avoid sudden changes in pressure during system start-up, shutdown, operation, cleaning, maintenance, etc., as well as exceeding the maximum withstand pressure specified in this manual, to prevent possible membrane breakage, sealing, etc. End fall off, membrane shell cracking and other serious damage consequences; this series of products have been treated with anti-corrosion and membrane wire protection before leaving the factory, and the inner membrane wire of the module is in a semi-dry state. For manual operation, the water production rate should be set to 50% of the design water production rate, and the initial water production must be discharged directly and cannot be used as product water.

Product usage tips

The normal start-up and normal cleaning and maintenance of the UF system are the key to ensure the long-term normal use of membrane products. Before starting the system, it should be ensured that the parameters of each valve, instrument, pre-processing equipment, signal transmission equipment, power equipment, etc. meet the design specifications and requirements, so as to ensure the safe, stable and up-to-standard operation of the overall system. Please refer to the product technical manual for the debugging and testing work of the system in the early stage.

Disclaimer

Failure to operate in strict accordance with the operating limits and guidelines set forth herein voids our limited warranty. If the UF system is out of service, please inject protective liquid inside the membrane module for anti-corrosion treatment, so as to avoid the increase of maintenance cost caused by the large number of microorganisms in the system.

UF specifications and models Membrane material Operation mode Membrane element size (mm) Effective membrane area (㎡) Nominal filter pore size (μm)
SNU-HI-1-H60 PES inside-out Φ225*1708 46 0.01

Note: The element model (membrane performance, appearance size) not mentioned can be customized according to the order quantity.

Send your message to this supplier
Send Now

High Toughness PES MBR Membrane 46m2 Surface Area 225×1708mm Polyacrylonitrile Membrane

Ask Latest Price
Brand Name :
SINOMEMB
Model Number :
SNU-HI-1-H60
Certification :
NSF
Place of Origin :
China
MOQ :
5
Packaging Details :
Standard export packaging
Contact Supplier
High Toughness PES MBR Membrane 46m2 Surface Area 225×1708mm Polyacrylonitrile Membrane
High Toughness PES MBR Membrane 46m2 Surface Area 225×1708mm Polyacrylonitrile Membrane

Sinomemb Environment Technology (beijing) Co.,

Verified Supplier
1 Years
beijing, beijing
Since 2016
Business Type :
Manufacturer
Total Annual :
10000000-15000000
Employee Number :
101~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement