| Supply Voltage | VCC | Operating, TJ < TJ(max) | 4.0 | | 24 | V |
| Reverse Supply Voltage | VRCC | | | | -18 | V |
| Under Voltage Lockout | VCC(UV) | VCC from 0 5 V or 5 0 V | | | 3.95 | V |
| Supply Current | ICC | Output OFF (VOUT = High) | | 8.5 | 13 | mA |
| Supply Current | ICC | Output ON (VOUT = Low) | | 8.5 | 13 | mA |
| Power-On Time | tPO | fOP < 200 Hz | | | 2 | ms |
| Low Output Voltage | VOUT(SAT) | IOUT = 10 mA, Output = ON | | 165 | 350 | mV |
| Output Current Limit | IOUT(LIM) | Output = ON (VOUT = Low), measured with RPULLUP = 0 , TJ < TJ(MAX) | 30 | 55 | 85 | mA |
| Output Leakage Current | IOUT(OFF) | Output = OFF, VOUT = 24 V | | | 10 | A |
| Output Rise Time | tr | 10% - 90%, VPU = 12V, RPULLUP = 1 k, CL = 4.7 nF | | 10 | | s |
| Output Fall Time | tr | 90% - 10%, VPU = 12V, RPULLUP = 1 k, CL = 4.7 nF | | 0.6 | | s |
| Minimum Operational Frequency | fOPmin | Allegro reference target | 0 | | | kHz |
| Maximum Operational Frequency | fOPmax | Allegro reference target | | 20 | | kHz |
| Maximum Operational Frequency | fOPmax | Allegro reference target, double-bandwidth option, suffix -H | | 40 | | kHz |
| Analog Signal Bandwidth | f-3dB | Cutoff frequency for low-pass filter | | 20 | | kHz |
| Analog Signal Bandwidth | f-3dB | Cutoff frequency for low-pass filter, double- bandwidth option | | 40 | | kHz |
| Operate Point | BOP | % of VPROC(PKPK), Output OFF to ON | | 70 | | % |
| Release Point | BRP | % of VPROC(PKPK), Output ON to OFF | | 30 | | % |
| Lockout Enable | VLOE | VPROC(PKPK) < VLOE = Output Switching Disabled | | 250 | | mV |
| Lockout Release | VLOR | VPROC(PKPK) > VLOE = Output Switching Enabled | | 350 | | mV |
| Calibration | CALI | First Output Edge fOP < 600 Hz, VCC > VCC(MIN) | | 1 | | tooth |
| Initial Calibration | CALI | 8 edge | | 3 | 8 | edge |
| Operational Air Gap Range | AG | | 0.75 | | 3 | mm |
| Direction Output Delay | td | Delay between first XOR SPEED output transition and reported direction change | | 400 | | ns |
| Maximum Sudden Air Gap Change / Signal Reduction | BIN | Differential magnetic signal reduction due to instantaneous air gap change; symmetrical signal reduction, fOP < 500 Hz, VPROC(PKPK) > VLOE after sudden air gap change | | 40 | | % |
| Duty Cycle Variation | D | Valid for SPEED(OUTA) and SPEED(OUTB) | 40 | 50 | 60 | % |
| Minimum Operating Signal | BIN | fOP < 10,000 Hz, Output switching (no missed edges) | | 30 | | G |
| Minimum Operating Signal | BIN | fOP 10,000 Hz, Output switching (no missed edges) | | 60 | | G |