Three-Phase Microprocessor Relay Test Set Portable Secondary Current Injection Test Set
|
| Technical Indicator | Specific Parameters |
|---|---|
| AC Current Output |
Phase current: 0~40A (RMS) 3-phase parallel: 0~120A (RMS) Long-time phase current: 10A Max output power: 450VA (phase) 900VA (3-phase parallel) |
| DC Current Output |
Phase current: 0~±10A 3-phase parallel: 0~±30A Output precision: 0.5% |
| AC Voltage Output |
Phase voltage: 0~120V (RMS) Line voltage: 0~240V (RMS) Output precision: 0.2% Max output power: 80VA (phase), 100VA (line) |
| DC Voltage Output |
Phase voltage: 0~±160V Line voltage: 0~±320V Output precision: 0.5% Max output power: 70VA (phase), 140VA (line) |
| Frequency Range |
Fundamental frequency: 0~1000Hz Harmonic order: 0~20 |
| Digital I/O |
10 channels digital input 8 channels digital output (relay dry contact, DC 220V/0.2A, AC 220V/0.5A) |
| Time Measurement |
Range: 0.1ms~9999s Accuracy: <0.1ms |
| Display | 6.4" TFT true-color LCD touchscreen |
| Power Supply | AC 220V±10% 50Hz/60Hz |
| Auxiliary DC Power Output | 110V/220V two gears, rated current 1.5A |
| Working Environment |
Temperature: 0~50℃ Relative humidity: <85% (no condensation) |