Specifications
Model Number :
TMSML1PB29
DHW Function :
Domestic hot water
Packaging Details :
(Color) General Carton package with Foam. Packing size: 795x490x330mm
Combustion Mode :
Full premix combustion
MOQ :
100PCS
Delivery Time :
10-15days
Warranty :
2years
Heat Exchanger Structure :
Primary heat exchanger
Certification :
CE, CSA, ISO9001.
Heating Circuit :
Closed heating circuit
Payment Terms :
L/C,D/A,D/P,T/T
Installation Requirement :
Must be installed by qualified gas engineer
Brand Name :
SHUANGMEI
Heating Function :
Space heating supply
Place of Origin :
Zhongshan City, Guangdong Province, China
DHW Circuit :
Independent hot water circuit
Price :
210-280 dollars
Service Cycle :
Regular annual maintenance recommended
Supply Ability :
20,000Pcs/Month
Fault Prompt :
Digital fault code display
After Sales Service :
Remote technical support
Description
Complete Combustion Technology Wall-Mounted Gas Combi Boiler

A gas-saving heating solution engineered for reliable domestic hot water and central heating performance.

Product Specifications
Product Type Wall-mounted Combi Gas Boiler Place of Origin China
Brand OEM Optional Operation Touch control
Panel Material Coated panel Installation Wall Mounted
Capacity 12L / 13L / 14L / 16L / 18L / 20L Version Non-condensing
Circulating Pump Built-in circulation pump DHW Heat Exchanger Material Stainless steel plate
Anti-freeze Function Automatic anti-freeze protection Dry-burn Protection Dry burn shutdown protection
Pump Anti-block Pump anti-seize function Gas Pressure Stabilize Gas pressure stabilization
Safety Valve Integrated safety relief valve Flow Sensor Flow sensor trigger
Constant Temp Mode DHW constant temperature mode Noise Design Low noise structure
Certification CE Customization Support OEM logo & outer carton customization
Service Life Long service life under proper maintenance
Key Features
  • 1.Modular internal layout helps technicians quickly replace spare parts.
  • 2.Adjustable water flow rate meets different domestic hot water demands.
  • 3.Integrated bypass valve protects the system under blocked pipeline conditions.
  • 4.Hot water priority mode gives priority to bath hot water demand.
  • 5.Smooth temperature transition avoids sudden hot water temperature surges.
Low Water Pressure Startup

This combi boiler supports low water pressure startup, making it suitable for high-rise buildings and communities with unstable tap water pressure. Even under low inlet water pressure conditions, the flow sensor can detect the water signal normally and activate hot water heating. Homeowners living on high floors no longer need to worry about weak water flow and failure to start the hot water function.

Built-in Circulating Pump Performance

The built-in circulating pump drives heating water circulating inside radiators or underfloor heating pipes. The pump speed can be adjusted to match different pipeline resistance for small or large heating systems. Anti-blocking protection activates regular short rotation during long idle periods, preventing impeller rust and seizure so the pump can restart smoothly after months of standby.

Pump overheat protection continuously monitors pump winding temperature. If pump overload leads to a rapid temperature rise, the boiler reduces load or shuts down the pump automatically to avoid coil burnout and pump failure, which would interrupt whole-house heating.

Vibration isolation pads are fitted between the pump assembly and boiler frame to reduce vibration transfer to the wall and connected pipelines, lowering resonance noise and protecting pipe joints from vibration fatigue cracking over long-term operation.

Frequently Asked Questions

Q1: What clearance is required around the boiler for maintenance?

A1: 15 cm side clearance and 40 cm front space for service.

Q2: Can the boiler be installed inside a kitchen cabinet?

A2: Sufficient ventilation space is required; follow local gas code.

Q3: Must a gas shut-off valve be installed?

A3: Yes, an isolation valve must be installed before the boiler gas inlet.

Q4: What is the pre-commissioning check list?

A4: Gas tightness test, water pressure test, flue leakage check, and electrical earth test.

Q5: Can a non-certified plumber install the boiler?

A5: No. Gas appliances must be installed by a qualified registered gas engineer.

Q6: What is system flushing?

A6: Cleaning sludge, rust, and debris from radiators and pipes before commissioning.

Send your message to this supplier
Send Now

Complete Combustion Technology Wall Mounted Gas Combi Boiler Gas-saving Low Water Pressure Startup Wall Hung Gas Combi Boiler

Ask Latest Price
Model Number :
TMSML1PB29
DHW Function :
Domestic hot water
Packaging Details :
(Color) General Carton package with Foam. Packing size: 795x490x330mm
Combustion Mode :
Full premix combustion
MOQ :
100PCS
Delivery Time :
10-15days
Contact Supplier
Complete Combustion Technology Wall Mounted Gas Combi Boiler Gas-saving Low Water Pressure Startup Wall Hung Gas Combi Boiler
Complete Combustion Technology Wall Mounted Gas Combi Boiler Gas-saving Low Water Pressure Startup Wall Hung Gas Combi Boiler

Zhongshan ShuangMei Electric Appliance Co., Ltd

Verified Supplier
1 Years
guangdong, zhongshan
Since 2015
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
50,000,000$-60,000,000$
Employee Number :
60~80
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement