HRMS-45 Digital Surface Rockwell Hardness Tester
The HRMS-45 digital surface Rockwell hardness tester is an advanced instrument featuring large screen digital display and touch operation. This sophisticated equipment allows for selection of surface Rockwell hardness scales, digital display of test data, and conversion between various hardness values. The system includes comprehensive functionality for test data storage, printout capabilities, and RS-232 super terminal configuration, delivering exceptional stability and intuitive operation.
Scope of Application
- Surface hardened steel
- Material surface heat treatment and chemical treatment
- Copper, aluminum alloy and other thin plates
- Galvanized, chrome-plated, tin-plated materials
- Bearing steel, chilled castings
Technical Parameters
| Parameter |
Specification |
| Initial Testing Force |
3Kg (29.42N) |
| All Testing Force |
15Kg (147.1N), 30Kg (294.2N), 45Kg (441.3N) |
| Indication of Hardness Value |
Digital Display |
| Duration Time |
0~60s |
| Max Height of Specimen |
200mm |
| Max Width of Specimen |
165mm |
| Dimension (DxWxH) |
520X215X700(mm) |
| Net Weight |
65Kg |
| Power Supply |
AC220V±5%, 50~60Hz (Voltage can be customized to AV110V±5%) |
| Standard Accessories |
3 pcs Standard Superficial Rockwell hardness block, Diamond Rockwell Hardness Indenter, Diameter 1.5875mm Ball Indenter (one for each), Testing Table (big, medium, "V"), Weight (a, b, c), Power cord |
| Optional Accessories |
Diameter 3.175mm Steel Ball Indenter |
Frequently Asked Questions
1. How do you perform a hardness test?
A hardness test is typically performed by pressing a specifically dimensioned and loaded object (indenter) into the surface of the material you are testing. The hardness is determined by measuring the depth of indenter penetration or by measuring the size of the impression left by an indenter.
2. How do I find my Rockwell hardness number?
The Rockwell hardness number is calculated from the depth of permanent deformation of the indenter into the sample, i.e. the difference in indenter position before and after application of the major load. The minor and major loads can be applied using dead weights or springs.
3. How often should a durometer be calibrated?
Unless otherwise requested, the calibration interval on your durometer will be one year. Several factors should be taken into consideration such as: the required accuracy vs. the instruments accuracy, the impact an out of tolerance reading will have on the process, and the performance history.