220V 50Hz Helmet Vision Measuring Machine, Helmet Peripheral Vision Meter
Helmet Tester Helmet Vision Measuring Machine Helmet Peripheral Vision Meter
Key Features
- Head mold fixed base and head mold use socket-type link for convenient and fast placement
- Composite pointer allows easy testing of left/right horizontal field of view and up/down field of view
- LED digital display shows angle scale for real-time field of view data monitoring
- Head mold specially processed according to standard field of view planes for fast and convenient testing
Technical Parameters
| Model | ZL-1812 |
| Horizontal Field of View (Left/Right) | ±150° |
| Vertical Field of View (Up/Down) | ±90° |
| Field of View Resolution | 1° |
| Operating Power | 220V, 50Hz |
Result Determination
According to GB811-2010 motorcycle member helmets standard, the helmet field of view must meet:
- Left and right horizontal field of view not less than 105°
- Upper field of view not less than 7°
- Lower field of view not less than 45°
Applicable Standards
CE, ASTM, GB811-2010 and related standards
Product Documentation
Safety Helmet Testing Machine.pdf