Cheapest Tilt Switch Sensor For Level Control Hydraulic Cylinder
Description
LCA341A is RION company integrated control core unit developed a dual axis digital type tilt switch sensor which built-in relay output circuit , application for level safety alarming and platform level detection ...etc related industry field . Alarm threshold value is pre-setable. when the inclination exceed set alarm value, it will output a no contact relay signal(drive current 1A) , to open the valve to control the corresponding hydraulic leg leveling . Product design precision , further compensation on the temperature and linearity , integrated the comprehensive protection function for the short circuit, instant high voltage , polarity ,swell ...etc. Suitable for all kinds of harsh industrial environment.Also adopts industrial-gradeMCU, three proofing PCB board, imported cable, wide temperature metal shell...etc all kinds of measures to improve the industrial level of the product on it’s reliability and stability .
Feature
Application
|  			 Measuring rang  |  			 			 ±15  |  			 			 °  |  		
|  			 Measuring axis  |  			 			 X ,Y axis  |  			 			 
  |  		
|  			 Resolution  |  			 			 0.05  |  			 			 °  |  		
|  			 Absolute accuracy  |  			 			 0.1  |  			 			 °  |  		
|  			 Long term stability  |  			 			 0.05  |  			 			 
  |  		
|  			 Zero temperature coefficient  |  			 			 -40~85℃ ±0.006  |  			 			 °/℃  |  		
|  			 Sensitivity temperature coefficient  |  			 			 -40~85℃ ≤100  |  			 			 ppm/℃  |  		
|  			 Power on time  |  			 			 0.1  |  			 			 S  |  		
|  			 Response time  |  			 			 0.2  |  			 			 s  |  		
|  			 EMC  |  			 			 According to EN61000 and GBT17626  |  		
|  			 MTBF  |  			 			 ≥50000 hours/time  |  		
|  			 Insulation Resistance  |  			 			 ≥100M  |  		
|  			 Shockproof  |  			 			 100g@11ms,3Times/Axis(half sinusoid))  |  		
|  			 Anti-vibration  |  			 			 10grms,10~1000Hz  |  		
|  			 Protection glass  |  			 			 IP67  |  		
|  			 Cables  |  			 			 Standard 1M length,wearproof,grease proofing,wide temperature, Shielded cables 4*0.4mm2  |  		
|  			 Weight  |  			 			 150g(without cable)  |  		
Electronic Characteristics
|  			 Power supply  |  			 			 Standard  |  			 			 9  |  			 			 12,24  |  			 			 36  |  			 			 V  |  		
|  			 Alarm output current  |  			 			 
  |  			 			 
  |  			 			 
  |  			 			 1000  |  			 			 M A  |  		
|  			 Working current  |  			 			 No-load  |  			 			 
  |  			 			 40  |  			 			 
  |  			 			 M A  |  		
|  			 Working temperature  |  			 			 
  |  			 			 -40  |  			 			 
  |  			 			 +85  |  			 			 ℃  |  		
|  			 Store temperature  |  			 			 
  |  			 			 -55  |  			 			 
  |  			 			 +125  |  			 			 ℃  |