This actuator is suitable for use in over 90% of explosive gas atmospheres, excluding underground coal mines. Its motor and electronic components feature flameproof treatment.
The machining precision of all mating surfaces is strictly controlled and inspected at the supplier level, ensuring the flameproof gap is sufficiently narrow to contain internal sparks. The aluminum housing is high-pressure die-cast using a larger tonnage press than standard electric actuators, resulting in a denser structure capable of withstanding significantly higher explosion pressures.
All mating surfaces between enclosure parts are designed in accordance with ATEX and UL standards, precisely machined, and tested prior to assembly to guarantee the explosion-proof rating. Installation is simplified via standard ISO5210 multi-flange mounting and double square drive.
| Type | Ex05E | Ex10E | Ex20E | Ex40E | Ex60E |
|---|---|---|---|---|---|
| Power | AC110V/AC220V | ||||
| Output Torque | 50Nm | 100Nm | 200Nm | 400Nm | 600Nm |
| Acting Time | 20S | 30S | 30S | 30S | 45S |
| Turning Angle | 0-90° | 0-90° | 0-90° | 0-90° | 0-90° |
| Motor Power | 10W | 25W | 40W | 90W | 90W |
| Rated Current | 0.24/0.15A | 0.57/0.30A | 0.63/0.35A | 1.12/0.64A | 1.18/0.67A |
| Total Weight | 3.0kg | 5.0kg | 5.5kg | 9.5kg | 10.0kg |
| Input Signal | 4-20mADC,1-5VDC,2-10VDC | ||||
| Output Singal | 4-20mADC | ||||
| Basic Error | not more than ±1% | ||||
| Reciprocating Error | not more than 1% | ||||
| Dead Space | 0.5%-5.0% adjustable | ||||
| Damping Characteristic | 0 times | ||||
| Repeating Error in Actuator | ≤1% | ||||
| Insulating Resistance | 100MΩ/500VDC | ||||
| Withstand Voltage Class | 1500VAC 1minutes | ||||
| Protection Class | IP67 | ||||
| Explosive-proof grade | Exd II BT4Gb | ||||
| Installation Angle | 360°at any angle | ||||
| Electric Interface | 2-M20*1.5 explosion-proof plug,clients should install corresponding explosion-proof cable connector when using according to the cable selected. | ||||
| Ambient Temperature | -20℃~+60℃ | ||||
| Optional Function | Over-torque protector/Dehumidify Heater/Passive contact switch | ||||
| Remark | Any other input or output signal needed, please specified in purchase order. | ||||