The DCL-Ex series fire-safe electric actuators are designed with a fail-safe function. Following an explosion or emergency shutdown, once backup power is restored, the actuator will automatically drive the valve to a pre-set safe position—such as full open or full close—even if the external control signal is unavailable. In addition, the self-locking mechanism ensures the valve remains securely at its last known position without hunting or unintended movement.
The DCL-Ex series actuators are suitable for more than 90% of explosive gas environments, excluding coal mine (colliery) applications. With proven field performance, over 10,000 DCL explosion-proof actuators have been operating safely for more than a decade in hazardous industrial environments.
All DCL-Ex actuators have undergone rigorous testing conducted by CSA, covering both Zone and Division systems in full compliance with UL and CSA standards. ATEX certification has been obtained, while CE and RoHS 3 compliance have been verified through testing by SGS.
| Type | Ex05E | Ex10E | Ex20E | Ex40E | Ex60E |
|---|---|---|---|---|---|
| Power | AC110V/AC220V | ||||
| Output Torque | 50Nm | 100Nm | 200Nm | 400Nm | 600Nm |
| Acting Time | 20S | 30S | 30S | 30S | 45S |
| Turning Angle | 0-90° | 0-90° | 0-90° | 0-90° | 0-90° |
| Motor Power | 10W | 25W | 40W | 90W | 90W |
| Rated Current | 0.24/0.15A | 0.57/0.30A | 0.63/0.35A | 1.12/0.64A | 1.18/0.67A |
| Total Weight | 3.0kg | 5.0kg | 5.5kg | 9.5kg | 10.0kg |
| Input Signal | 4-20mADC,1-5VDC,2-10VDC | ||||
| Output Singal | 4-20mADC | ||||
| Basic Error | not more than ±1% | ||||
| Reciprocating Error | not more than 1% | ||||
| Dead Space | 0.5%-5.0% adjustable | ||||
| Damping Characteristic | 0 times | ||||
| Repeating Error in Actuator | ≤1% | ||||
| Insulating Resistance | 100MΩ/500VDC | ||||
| Withstand Voltage Class | 1500VAC 1minutes | ||||
| Protection Class | IP67 | ||||
| Explosive-proof grade | Exd II BT4Gb | ||||
| Installation Angle | 360°at any angle | ||||
| Electric Interface | 2-M20*1.5 explosion-proof plug,clients should install corresponding explosion-proof cable connector when using according to the cable selected. | ||||
| Ambient Temperature | -20℃~+60℃ | ||||
| Optional Function | Over-torque protector/Dehumidify Heater/Passive contact switch | ||||
| Remark | Any other input or output signal needed, please specified in purchase order. | ||||