Robust die cast aluminum alloy housing fire safe compact actuator / IP67 Waterproof
Features
Description
DCL fire-safe compact electric actuators can be powered by a wide range of voltages, including 24VDC, 24VAC, 110VAC, 220VAC, 380VAC, and 440VAC. The integrated design combining the motor, housing, and control module makes DCL explosion-proof actuators the most compact models within their torque range.
The machining accuracy of the enclosure is 100% inspected and precisely controlled by DCL to ensure maximum safety in the event of an explosion. Each actuator also undergoes a full underwater sealing test to verify protection levels of IP68 and NEMA 7.
All DCL actuators are rigorously tested and certified by CSA according to UL and CSA standards. CSA certification for both Zone and Division systems is expected in Q4 2020, and the product has been ATEX certified by an EU-authorized certification body.
Specification
| Type | Ex05E | Ex10E | Ex20E | Ex40E | Ex60E |
|---|---|---|---|---|---|
| Power | AC110V/AC220V | ||||
| Output Torque | 50Nm | 100Nm | 200Nm | 400Nm | 600Nm |
| Acting Time | 20S | 30S | 30S | 30S | 45S |
| Turning Angle | 0-90° | 0-90° | 0-90° | 0-90° | 0-90° |
| Motor Power | 10W | 25W | 40W | 90W | 90W |
| Rated Current | 0.24/0.15A | 0.57/0.30A | 0.63/0.35A | 1.12/0.64A | 1.18/0.67A |
| Total Weight | 3.0kg | 5.0kg | 5.5kg | 9.5kg | 10.0kg |
| Input Signal | 4-20mADC,1-5VDC,2-10VDC | ||||
| Output Singal | 4-20mADC | ||||
| Basic Error | not more than ±1% | ||||
| Reciprocating Error | not more than 1% | ||||
| Dead Space | 0.5%-5.0% adjustable | ||||
| Damping Characteristic | 0 times | ||||
| Repeating Error in Actuator | ≤1% | ||||
| Insulating Resistance | 100MΩ/500VDC | ||||
| Withstand Voltage Class | 1500VAC 1minutes | ||||
| Protection Class | IP67 | ||||
| Explosive-proof grade | Exd II BT4Gb | ||||
| Installation Angle | 360°at any angle | ||||
| Electric Interface | 2-M20*1.5 explosion-proof plug,clients should install corresponding explosion-proof cable connector when using according to the cable selected. | ||||
| Ambient Temperature | -20℃~+60℃ | ||||
| Optional Function | Over-torque protector/Dehumidify Heater/Passive contact switch | ||||
| Remark | Any other input or output signal needed, please specified in purchase order. | ||||