Product Description
  12v dc ac 220v pure sine wave inverter 1000W
  Description:
  Power inverter is a kind of products which change the DC electricity to AC electricity. It has been widely used in cars, steamboats, mobile offering post and telecommunications, public security, emergency and other field.
  This power inverter has adopted the international lead circuit design, with the advantage of small size, light, stable, and high conversion efficiency. It has five kind of protect function such as: input under voltage protection, input over voltage protection, overload protection, over temperature protection, output short circuit protection.
   
  Features:
  Pure sine wave output ( THD < 3% ) 
  Input & output completely isolated design
  High efficiency93%
  Loading and temperature controlled the cooling fan.
  Protection: input low voltage alarm & shutdown, overload,short circuit, input over voltage, over temperature, reverse polarity
  USB output port 5V2.1A
   With Remote controller function /CR80 /CRD80 /CRD99 Remote controller with 5m cable optional,wireless remote controller optional.
  LCD display function optional
  2 years quality warranty, technical supporting whole life.
  pure sine wave inverter specifications:
      	 		 			|  			 MODEL  			 |  			 			 FS1000D-112  			 |  			 			 FS1000D-124  			 |  			 			 FS1000D-148  			 |  			 			 FS1000D-212  			 |  			 			 FS1000D-224  			 |  			 			 FS1000D-248  			 |  		
 		 			|  			 Output  			 |  			 			 AC Voltage  			 |  			 			 100/110/120VAC  			 |  			 			 220/230/240VAC  			 |  		
 		 			|  			 Rated Power  			 |  			 			 1000W  			 |  		
 		 			|  			 Surge Power  			 |  			 			 Load 120~150%(3min.);2000W(3sec;resistive)  			 |  		
 		 			|  			 Waveform  			 |  			 			 Pure Sine Wave(THD<3%)  			 |  		
 		 			|  			 Frequency  			 |  			 			 50/60Hz ±0.05%  			 |  		
 		 			|  			 AC Regulation  			 |  			 			 ±5%  			 |  			 			 ±10%  			 |  		
 		 			|  			 Power Factor Allowed  			 |  			 			 COSθ-90°~COSθ+90°  			 |  		
 		 			|  			 Standard Receptacles  			 |  			 			 USA/British/Franch/Schuko /UK/Australia/Universal etc. optional  			 |  		
 		 			|  			 LED Indicator  			 |  			 			 Green for power on, red for faulty status  			 |  		
 		 			|  			 USB port  			 |  			 			 5V 2.1A  			 |  			 			 5V 2.1A  			 |  			 			 ------  			 |  			 			 5V 2.1A  			 |  			 			 5V 2.1A  			 |  			 			 ------  			 |  		
 		 			|  			 LCD display  			 |  			 			 voltage, power, protection status ( optional)  			 |  		
 		 			|  			 Remote control function  			 |  			 			 default  			 |  		
 		 			|  			 Remote controller  			 |  			 			 CR80/CRD80/CRW88/CRD99 optional  			 |  		
 		 			|  			 Input  			 |  			 			 No Load Current Draw  			 |  			 			 ≤0.80A  			 |  			 			 ≤0.70A  			 |  			 			 ≤0.70A  			 |  			 			 ≤0.80A  			 |  			 			 ≤0.70A  			 |  			 			 ≤0.70A  			 |  		
 		 			|  			 DC Voltage  			 |  			 			 12VDC  			 |  			 			 24VDC  			 |  			 			 48VDC  			 |  			 			 12VDC  			 |  			 			 24VDC  			 |  			 			 48VDC  			 |  		
 		 			|  			 Voltage Range  			 |  			 			 10.5~15VDC  			 |  			 			 21~30VDC  			 |  			 			 42~60VDC  			 |  			 			 10.5~15VDC  			 |  			 			 21~30VDC  			 |  			 			 42~60VDC  			 |  		
 		 			|  			 Efficiency(Typ.)  			 |  			 			 89%~93%  			 |  		
 		 			|  			 Fuse  			 |  			 			 40A×4  			 |  			 			 20A×4  			 |  			 			 10A×4  			 |  			 			 40A×4  			 |  			 			 20A×4  			 |  			 			 10A×4  			 |  		
 		 			|  			 Remote Control  			 |  			 			 Function (optional)  			 |  		
 		 			|  			 Protection  			 |  			 			 BAT. Low Alarm  			 |  			 			 10.5±0.5VDC  			 |  			 			 21±1.0VDC  			 |  			 			 42±2.0VDC  			 |  			 			 10.5±0.5VDC  			 |  			 			 21±1.0VDC  			 |  			 			 42±2.0VDC  			 |  		
 		 			|  			 BAT. Low Shutdown  			 |  			 			 10±0.5VDC  			 |  			 			 20±1.0VDC  			 |  			 			 40±2.0VDC  			 |  			 			 10±0.5VDC  			 |  			 			 20±1.0VDC  			 |  			 			 40±2.0VDC  			 |  		
 		 			|  			 Over Load  			 |  			 			 Shut down output voltage , restart to recover  			 |  		
 		 			|  			 Over Voltage  			 |  			 			 15.5±0.5VDC  			 |  			 			 31±1.0VDC  			 |  			 			 62±2.0VDC  			 |  			 			 15.5±0.5VDC  			 |  			 			 31±1.0VDC  			 |  			 			 62±2.0VDC  			 |  		
 		 			|  			 Over Temperature  			 |  			 			 Shut down output voltage , recover automatically after temperature goes down  			 |  		
 		 			|  			 Output Short  			 |  			 			 Shut down output voltage , restart to recover  			 |  		
 		 			|  			 DC Input Reverse Polarity  			 |  			 			 By fuse  			 |  		
 		 			|  			 Earth Fault  			 |  			 			 Shut off o/p when the load has electrical leakage  			 |  		
 		 			|  			 Soft Start  			 |  			 			 Yes, 3-5 Seconds  			 |  		
 		 			|  			 Environment  			 |  			 			 Working Temp.  			 |  			 			 0~+50℃  			 |  		
 		 			|  			 Working Humidity  			 |  			 			 20~90%RH non-condensing  			 |  		
 		 			|  			 Storage Temp.&Humidity  			 |  			 			 -30~+70℃,10~95%RH  			 |  		
 		 			|  			 Safety & EMC  			 |  			 			 Safety Standards  			 |  			 			 Certified UL 458(only for "GFCI" receptacles)  			 |  			 			 Certified EN 60950-1; 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013.  			 |  		
 		 			|  			 Isolation Resistance  			 |  			 			 I/P-O/P:100M Ohms/500VDC  			 |  		
 		 			|  			 EMI Conduction &  			Radiation  			 |  			 			 Certified FCC class A  			 |  			 			 Certified EN 62040-2:2006,EN61000-3-2; EN61000-3-3;  			 |  		
 		 			|  			 EMS Immunity  			 |  			 			 ------  			 |  			 			 Certified IEC61000-4-3, IEC61000-4-6  			 |  		
 		 			|  			 E-MARK  			 |  			 			 ------  			 |  			 			 Certified ECE RIO.05:2014  			 |  		
 		 			|  			 Others  			 |  			 			 Dimension(L×W×H)  			 |  			 			 313.5×173.6×103.1mm  			 |  		
 		 			|  			 Packing  			 |  			 			 2.9kg;4pcs/12.8kg/0.042m³  			 |  		
 		 			|  			 Cooling  			 |  			 			 Load control fan or by thermal control fan  			 |  		
 		 			|  			 Application  			 |  			 			 Home and Office appliances,Portable Power Equipment,Vehicle,Yacht and Off-Gid Solar  			power systems…etc.  			 |  		
 	 
   
  Product picures:
  

   
  FAQ:
   
  1,Q:Why your quotation is higher than other suppliers?
 A:In the Chinese market, many factories sell low-cost inverters, which are actually assembled by small unlicensed workshops,largely to cut costs and use substandard components for assembly. There's a major security breach SOLARWAY is a professinonal power inverter R & D, manufacturing and sales enterprises, we deeply cultivated the German market for more than 10 years, each year exports about 50,000-100,000 power inverter to Germany and its surrounding markets Our product quality is worthy of your trust!
 ..............................................................................................................................................................
 2,Q:How many categories does it have according to the output waveform ?
 A:Type one: our NM and NS series Modified Sine Wave inverter, which uses PWM pulse width modulation to generate modified sine wave. Due to the usage of intelligent dedicated circuit and high power field effect tube, it greatly reduces the power loss and increases the soft-start function, effectively ensuring the reliability of the inverter. If the power quality is not highly demanded, it is able to meet the needs of most electrical equipment. But it still exists 20% harmonic distortion problems when running sophisticated equipment, can also cause high-frequency interference to radio communications equipment. This kind of
 inverter can meet the basic needs of most of our power, high efficiency, small noise, moderate price, and thus become the mainstream products in the market.
 Type two: our NP, FS, NK series Pure Sine Wave inverter, which adopts isolated coupling circuit design, high efficiency, high stability of the output waveform, high-frequency technology, small in size, suitable for all kinds of load, can be connected to any common electrical devices and inductive load devices (such as refrigerators, electric drill, etc.) without any interference (eg: buzz and TV noise). The output of pure sine wave inverter is the same as the grid tie power we daily used, or even better, because it does not exist grid tie electromagnetic pollution..