Pure Sine Wave Inverter 2000w with bypass function
Description:
Notice:
 1. The 2000W inverter should be installed in a dry, well ventilated environment, keeping the inlet more than 20CM away from the wall.
 2. DC input is not reversed, otherwise the fuse blows, possible mosfet failure.
 3. Short-circuit fault, Restart after removing the fault, otherwise inverter damage.
 4. Non-professional please don’t open the 000W bypass inverter, because of the high voltage inside the inverter. When open by yourself without warranty.
pure sine wave inverter specifications:
|  			 MODEL  			 |  			 			 TFS2000-112  			 |  			 			 TFS2000-124  			 |  			 			 TFS2000-148  			 |  			 			 TFS2000-212  			 |  			 			 TFS2000-224  			 |  			 			 TFS2000-248  			 |  		|
|  			 Output  			 |  			 			 AC Voltage  			 |  			 			 100/110/120VAC  			 |  			 			 220/230/240VAC  			 |  		||||
|  			 Rated Power  			 |  			 			 2000W  			 |  		||||||
|  			 Surge Power  			 |  			 			 Load 120~150%(3min.);3000W(3sec; resistive)  			 |  		||||||
|  			 Waveform  			 |  			 			 Pure Sine Wave(THD<3%)  			 |  		||||||
|  			 Frequency  			 |  			 			 50/60Hz ±0.05%  			 |  		||||||
|  			 AC Regulation  			 |  			 			 ±5%  			 |  			 			 ±10%  			 |  		|||||
|  			 Power Factor Allowed  			 |  			 			 COSθ-90°~COSθ+90°  			 |  		||||||
|  			 Standard Receptacles  			 |  			 			 USA/British/Franch/Schuko /UK/Australia/Universal etc. optional  			 |  		||||||
|  			 LED Indicator  			 |  			 			 Green for power on, red for faulty status  			 |  		||||||
|  			 USB port  			 |  			 			 5V 2.1A  			 |  			 			 5V 2.1A  			 |  			 			 ------  			 |  			 			 5V 2.1A  			 |  			 			 5V 2.1A  			 |  			 			 ------  			 |  		|
|  			 LCD display  			 |  			 			 voltage, power, protection status ( optional)  			 |  		||||||
|  			 Remote control function  			 |  			 			 default  			 |  		||||||
|  			 Remote controller  			 |  			 			 CR80/CRD80 optional  			 |  		||||||
|  			 Input  			 |  			 			 No Load Current Draw  			 |  			 			 ≤1.1A  			 |  			 			 ≤0.80A  			 |  			 			 ≤0.70A  			 |  			 			 ≤1.1A  			 |  			 			 ≤0.80A  			 |  			 			 ≤0.70A  			 |  		
|  			 DC Voltage  			 |  			 			 12VDC  			 |  			 			 24VDC  			 |  			 			 48VDC  			 |  			 			 12VDC  			 |  			 			 24VDC  			 |  			 			 48VDC  			 |  		|
|  			 Voltage Range  			 |  			 			 10.5~15VDC  			 |  			 			 21~30VDC  			 |  			 			 42~60VDC  			 |  			 			 10.5~15VDC  			 |  			 			 21~30VDC  			 |  			 			 42~60VDC  			 |  		|
|  			 Efficiency(Typ.)  			 |  			 			 89%~93%  			 |  		||||||
|  			 Fuse  			 |  			 			 40A×6  			 |  			 			 20A×6  			 |  			 			 10A×6  			 |  			 			 40A×6  			 |  			 			 20A×6  			 |  			 			 10A×6  			 |  		|
|  			 Remote Control  			 |  			 			 Function (optional)  			 |  		||||||
|  			 Protection  			 |  			 			 BAT. Low Alarm  			 |  			 			 10.5±0.5VDC  			 |  			 			 21±1.0VDC  			 |  			 			 42±2.0VDC  			 |  			 			 10.5±0.5VDC  			 |  			 			 21±1.0VDC  			 |  			 			 42±2.0VDC  			 |  		
|  			 BAT. Low Shutdown  			 |  			 			 10±0.5VDC  			 |  			 			 20±1.0VDC  			 |  			 			 40±2.0VDC  			 |  			 			 10±0.5VDC  			 |  			 			 20±1.0VDC  			 |  			 			 40±2.0VDC  			 |  		|
|  			 Over Load  			 |  			 			 Shut down output voltage , restart to recover  			 |  		||||||
|  			 Over Voltage  			 |  			 			 15.5±0.5VDC  			 |  			 			 31±1.0VDC  			 |  			 			 62±2.0VDC  			 |  			 			 15.5±0.5VDC  			 |  			 			 31±1.0VDC  			 |  			 			 62±2.0VDC  			 |  		|
|  			 Over Temperature  			 |  			 			 Shut down output voltage , recover automatically after temperature goes down  			 |  		||||||
|  			 Output Short  			 |  			 			 Shut down output voltage , restart to recover  			 |  		||||||
|  			 DC Input Reverse Polarity  			 |  			 			 By fuse  			 |  		||||||
|  			 Earth Fault  			 |  			 			 Shut off o/p when the load has electrical leakage  			 |  		||||||
|  			 Soft Start  			 |  			 			 Yes, 3-5 Seconds  			 |  		||||||
|  			 Environment  			 |  			 			 Working Temp.  			 |  			 			 0~+50℃  			 |  		|||||
|  			 Working Humidity  			 |  			 			 20~90%RH non-condensing  			 |  		||||||
|  			 Storage Temp.&Humidity  			 |  			 			 -30~+70℃,10~95%RH  			 |  		||||||
|  			 Safety & EMC  			 |  			 			 Safety Standards  			 |  			 			 Certified UL 458(only for "GFCI" receptacles)  			 |  			 			 Certified EN 60950-1; 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013.  			 |  		||||
|  			 Isolation Resistance  			 |  			 			 I/P-O/P:100M Ohms/500VDC  			 |  		||||||
|  			 EMI Conduction &  			Radiation  |  			 			 Certified FCC class A  			 |  			 			 Certified EN 62040-2:2006,EN61000-3-2; EN61000-3-3;  			 |  		|||||
|  			 EMS Immunity  			 |  			 			 ------  			 |  			 			 Certified IEC61000-4-3, IEC61000-4-6  			 |  		|||||
|  			 E-MARK  			 |  			 			 ------  			 |  			 			 Certified ECE RIO.05:2014  			 |  		|||||
|  			 Others  			 |  			 			 Dimension(L×W×H)  			 |  			 			 325.2×281.3×112.7mm  			 |  		|||||
|  			 Packing  			 |  			 			 5.2kg;2pcs/11.1kg/0.053m³  			 |  		||||||
|  			 Cooling  			 |  			 			 Load control fan or by thermal control fan  			 |  		||||||
|  			 Application  			 |  			 			 Home and Office appliances,Portable Power Equipment,Vehicle,Yacht and Off-Gid Solar  			power systems…etc.  |  		||||||
Product picures:



About solarway:
 Jiaxing Solarway New Energy Company is a Sino-Germany Joint venture which is a professional off-grid power inverter manufacturer in Jiaxing city ,near to Shanghai,China . We are mainly engaged in high-tech DC TO AC inverter, DC TO DC converter, MPPT/PWM
 sollar controller, solar panel and other solar system accessories, OEM and ODM service are available.All our products we have CE,RoHs,E-mark,ETL certification .We have R & D Center and After-sales Service Center in Beijing, China and Leipzig, Germany to make sure we have new design with patent every year.