Advanced Metering Solutions Practical Flexible Expandable Data Read Remote Control Load Management
 
 Calin's AMI solutions are built up on  an annual basis of 80,000,000 pcs smart meter deployment process in China in the past one decades. China is one of the earliest country pioneering smart metering solutions in the world. Given huge population and grid scale basis, China AMI solutions tolerate zero theoretical fantacy or technical ads, being practical and feasible for implementation. Building a stable and sound automated meter reading system is the solid base of entire AMI setup. Getting connected is the core principle of the entire solution. Calin's expertise is groomed from an intense interactions in the fornt line of smart metering deployment field in China and will help utility or service providers to optimize their operation and thus generate solid profit by non-technical loss reduction and recovery  and better customer education as well as services.
  
 
 
 China smart meter installation in 1,000 pcs
 
 Calin's AMI solution must be practical, easy  to implement, flexibile to cover utility's daily operation, and expandable for helping utilities growing in both diversity of management and population to be served. Calin offers  broad portfolio of products and services in a simplified, subscription-based pricing structure for utilities. 
 
 Key Benefit
  - Analytics modules support improvements in many areas
  - Stable connection from the bottom layer to the head-end servers (HES)
  - Real-time data readout and remote load management as in intrusive controls
  - Encryption algorithms and digital certificates are utilized to keep utility data safe
  - Can start with entry level AMR AMM system for meter reading puposes
  - ODM and RD customization on clients' request
  
 China smart metering cost per capital
 
 
 AMI electricity meter Specification Datasheet
 
 
    |   Parameter   |    1 Phase   |    3 Phase   |  
  |   Nominal voltage   |    110/120/220/230/240V  Un (40%- 130%)   |    3x110/120/220/230/240V Un(30%- 135%)   |  
  |   Norminal current   |    5(60)A   |    10(100)A   |  
  |   Connection type   |    Whole current / CTVT connection   |    Whole current / CTVT connection   |  
  |   Maximum current   |    80A   |    100A   |  
  |   Frequency   |    50Hz   |    50Hz   |  
  |   Accuracy class    |    IEC Class.1   |    IEC Class.1   |  
  |   Voltage circuit burden   |    ≤1.5W & 1.2VA   |    ≤1.5W & 5VA   |  
  |   Current circuit burden   |    ≤0.2VA   |    ≤0.5VA   |  
  |   Protective class   |    IP 54 as  IEC 60529   |    IP54 as  IEC 60529   |  
  |   Insulation class   |    6kV Class II   |    6.5kV Class II   |  
  |   Surge immunity   |    4 kV   |    4.3kV   |  
  |   Electrostatic discharge   |    15kV   |    16kV air discharge   |  
  |   Immunity to HF fields   |    80MHz to 2GHz@30V/m   |    80MHz to 2GHz@30V/m   |  
  |   Fast transient burst   |    4.3kV   |    4.3kV   |  
  |   Radio interference   |    As CISPR22   |    As CISPR22   |  
  |   Battery life without power   |    10 years   |    10 years   |  
  |   Dimension   |    160mmx112mmx71mm   |    290mmx170mmx85mm   |  
  |   Weight   |    Approximate 0.7kg   |    Approximate 3kg   |