12.5-15kw In-Row Air Conditioners With High Efficient EC Fan For Computer Rooms Radiating
| Product Introduction Coolnet Cool-row (12.5-15kW) air-cooled in-row air conditioners provide a solution for cooling equipment near the equipment room. It is installed side by side with server cabinets and close to the heat source to solve the problems of mixing and short-circuiting of hot and cold air in conventional air conditioners, eliminating local hot spots, and increase the return air temperature and outlet air temperature, improve the cooling energy efficiency ratio, suitable for cold/hot aisle closed systems and micro-module systems. Advantages - Famous and excellent configuration, the system has high reliability, high efficiency, high sensible heat ratio and high stability;
- High temperature conditions (indoor return air temperature 35C/RH% 27℃, outdoor 35℃);
- Matching the load of the computer room, the system is reliable and stable, and the energy saving effect is good;
- Close to the cold source, precise cooling, and prevent hot spots;
- Power-off memory, self-starting when incoming calls; can realize group control networking, network monitoring and other functions;
- Energy saving effect of EC regulation;
|  |
| Structure & Components  | R410A environmentally friendly refrigerant - Dynamic cooling can quickly respond to changes in the thermal load of the computer room, greatly reducing the number of compressor starts and stops
- The compressor is placed in the outdoor unit, which can reduce the noise of the computer room, reduce the probability of maintaining the air-conditioning equipment in the computer room
Efficient EC centrifugal fan - Support top air supply/horizontal air supply/downward air supply/downward air supply
- Adopt stepless speed regulation EC centrifugal fan, energy saving 30%~40%, low noise. Automatically adjust according to the size of the load
Electronic Expansion Valve - Adjust the throttle of valve smoothly to save the energy
- Wide range og operations, which can help reduce the superheat degree and improvde EER Realize cooling capacity and heat load precise matching
- Qucik response, realize the precise cooling
|
 |
Technical Parameter
| Model | CRA013A | CRA020A | CRA040A | CRA050A | CRA060A |
| Air supply | Front/Side | Front/Side | Front | Front | Front |
| Power supply | 380VAC/3Ph/50Hz |
| Cooling capacity-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
| Sensible cooling-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
| Compressor |
| Refrigerant | R410A |
| Quantity | 1 |
| Fan |
| Fan type | EC Centrifugal fan |
| Quantity | 4 | 5 | 2 | 3 | 3 |
| Air volume-m3/h | 3200 | 5000 | 8800 | 11000 | 12500 |
| Heater |
| Heat type | PTC | | | | |
| Capacity-KW | 2 | 3 | 6 | 6 | 6 |
| Humidification |
| Capacity-KW | 1 | 1.5 | 3 | 3 | 3 |