Blade Type Power Connector Assemblies RoHS The table consolidates the technical and commercial attributes stored for this exact listing.
| Parameter | Recorded Value |
|---|---|
| Brand Name | Anderson Power |
| Model Number | 6329G1 |
| Description | Blade Type Power Connector Assemblies RoHS |
| Minimum Order Quantity | 1 |
| Packaging Details | - |
| Delivery Time | 7-13 working days |
| Stock | 642 |
Model-specific drawings, land patterns, mating orientation, and reel specifications should be checked against the latest manufacturer document for 6329G1 before PCB release.
The innovative SB connectors provide cost-effective reliability, design flexibility and safety for your products' manufacture, installation and maintenance. APP's 2 & 3 pole connectors are available with a 175 amp rating, 600 Volts continuous AC or DC operation. There are SB connectors for many applications and wire sizes, #4 to 1/0 AWG (21.1 to 53.5mm). Mechanical keys ensure connectors will only mate with connectors of the same color. Different color housings are selected to identify voltages, thus preventing mismatching of the power supply system.
| Part Number | Description | Housing Color | Wire Size (AWG) | Wire Size (sq. mm) | Voltage Rating (Volts) | Current Rating (Amperes) | Contact/Disconnect Cycles | Contact Resistance (micro-ohms) | Contact Retention Force (lbf) | Insulation Withstanding Test Voltage (Volts AC/DC) | Max. Wire Insulation Diameter (inches) | Max. Wire Insulation Diameter (mm) | Operating Temperature (C) | Operating Temperature (F) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 6325G1 | 2 Pole Housing & 175 amp Contacts | Gray | 1/0 | 53.5 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6326G1 | 2 Pole Housing & 175 amp Contacts | Blue | 1/0 | 53.5 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6327G1 | 2 Pole Housing & 175 amp Contacts | Orange | 1/0 | 53.5 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6328G1 | 2 Pole Housing & 175 amp Contacts | Yellow | 1/0 | 53.5 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6329G1 | 2 Pole Housing & 175 amp Contacts | Red | 1/0 | 53.5 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6325G5 | 2 Pole Housing & 175 amp Contacts | Gray | #2 | 33.6 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6326G5 | 2 Pole Housing & 175 amp Contacts | Blue | #2 | 33.6 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6327G5 | 2 Pole Housing & 175 amp Contacts | Orange | #2 | 33.6 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6328G5 | 2 Pole Housing & 175 amp Contacts | Yellow | #2 | 33.6 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6329G5 | 2 Pole Housing & 175 amp Contacts | Red | #2 | 33.6 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6325G6 | 2 Pole Housing & 175 amp Contacts | Gray | #4 | 21.1 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6326G6 | 2 Pole Housing & 175 amp Contacts | Blue | #4 | 21.1 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6327G6 | 2 Pole Housing & 175 amp Contacts | Orange | #4 | 21.1 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6328G6 | 2 Pole Housing & 175 amp Contacts | Yellow | #4 | 21.1 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6329G6 | 2 Pole Housing & 175 amp Contacts | Red | #4 | 21.1 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 940 | Housing Only | Gray | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| 941 | Housing Only | Blue | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| 942 | Housing Only | Orange | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| 943 | Housing Only | Yellow | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| 949 | Housing Only | Red | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| 2-7252G11 | Housing Only | Black, no voltage key | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| 944 | 175 amp Contacts (set of 2) | N/A | 1/0 | 53.5 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 1382 | 175 amp Contacts (individual) | N/A | 1/0 | 53.5 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 947 | 175 amp Contacts (set of 2) | N/A | #2 | 33.6 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 1383 | 175 amp Contacts (individual) | N/A | #2 | 33.6 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 948 | 175 amp Contacts (set of 2) | N/A | #4 | 21.1 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 1384 | 175 amp Contacts (individual) | N/A | #4 | 21.2 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 948G1* | 175 amp Contacts (set of 2) | N/A | #6 | 13.3 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 1348* | 175 amp Contacts (individual) | N/A | #6 | 13.3 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 944G1 | 175 amp Contacts (set of 2) | N/A | #1 | 42.4 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 1347 | 175 amp Contacts (individual) | N/A | #1 | 42.4 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 180BBS | Bus bar contact | N/A | N/A | N/A | 600 | 175 | To 10,000 | 100 | 300 | 2200 | N/A | N/A | -20 to 105 | -4 to 221 |
| 6316 | 3 Pole Housing & 175 amp Contacts | Gray | 1/0 | 53.5 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6316G9 | 3 Pole Housing & 175 amp Contacts | Gray | #1 | 42.4 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 6316G10 | 3 Pole Housing & 175 amp Contacts | Gray | #2 | 33.6 | 600 | 175 | To 10,000 | 100 | 300 | 2200 | 0.75 | 19.01 | -20 to 105 | -4 to 221 |
| 902 | 3 Pole Housing Only | Gray, springs & hardware | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| Part Number | Description |
|---|---|
| 995G1 | Handle, hardware & lock washers - Gray |
| 995G3 | Handle, hardware & lock washers - Red |
| 923 | Manual release, locking half with clamps and hardware |
| 924 | Manual release, mounting half with clamps and hardware |
| 110G56 | Lock nut for use with Bus bar contact |
| SB175-lockout | Safety lockout |
| 111197G1 | Charger key |
| 134G2 | Dust cover |
| 945 | Cable clamps |
| 945G3 | Cable clamps-2 single conductor with hardware. Use with "A" frame only. |
| 946G1 | Cable clamps-1 twin conductor with hardware. Use with "A" frame only. |
| Part Number | Description | Wire Size (AWG) | Wire Size (sq. mm) |
|---|---|---|---|
| 5648 | Use with 944 | 1/0 to #10 | 53.5 to 5.1 |
| 5663 | Use with 944 | 1/0 to #6 | 53.5 to 13.3 |
| 5687 | Use with 944 | 1/0 to #1 | 53.5 to 42.4 |
| 5690 | Use with 944 | 1/0 to #2 | 53.5 to 33.6 |
| 5693 | Use with 944 | 1/0 to #4 | 53.5 to 21.2 |
| Part Number | Description |
|---|---|
| 1368 | Hand tool for 1/0 to #1 (53.5/42.4) |
| 1387G1 | Pneumatic tool |
| 1388G3 | - die for 1/0 to #1 (53.5/42.4) |
| 1388G5 | - die for #4 |
| 1389G5 | - locator for #4 |
| 1389G3 | - locator for 1/0 to #1 (53.5/42.4) |
| 1303G4 | - die for 1/0 to #4 (53.5/21.1) |
| 1304G4 | - locator for 1/0 to #4 (53.5/21.1) |
| Feature | Description |
|---|---|
| Mechanical keyed housings | Prevents accidental mating of components operating at different voltage levels |
| Flat wiping contact system | Allows for minimal contact resistance at high current, wiping action cleans contact surface during disconnection |
| Genderless design | Makes assembly quick and easy and reduces number of parts stocked |
The product record identifies Anderson Power as the brand and 6329G1 as the model. The listing is supplied by Shenzhen ECER Network Technology Co., Ltd., an electronic-component sourcing and supply company. The supplier identity is presented separately from the product brand; this page does not imply that ECER manufactures the branded connector.
Compliance evaluation should be based on documentation that identifies the exact model 6329G1, its revision, and the applicable material or product scope.
The current listing records an MOQ of 1. Confirm the final quantity break and pack multiple on the commercial quotation.
Match the reel or package label to brand Anderson Power and model 6329G1. Also compare contact count, pitch, contact orientation, and mounting style with the approved drawing and purchase order.
Use the manufacturer drawing and the agreed inspection standard as controlling documents. Inspect housing condition, contact coplanarity, plating appearance, terminal deformation, and the component interface before production release.
The listing records: -. Reels or trays should be immobilized inside rigid cartons and protected against moisture, impact, crushing, and electrostatic exposure appropriate to the component and shipping route.
Request lot identification, packing records, incoming inspection results, and any applicable manufacturer compliance declaration. Contractually required electrical or material reports should be named on the purchase order.
The listing records a lead time of 7-13 working days and stock of 642. Both are point-in-time commercial records and should be reconfirmed before order placement.
Retain the quotation, invoice, packing list, reel-label photographs, inspection results, and nonconformance records. Any return or corrective-action request should identify the lot, quantity, observed failure mode, and test conditions.